02.11.2012 Views

IBM IntelliStation - ps-2

IBM IntelliStation - ps-2

IBM IntelliStation - ps-2

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

96<br />

fan 1 fan 2<br />

fan 5<br />

Top view of planar<br />

fan 6<br />

(rear)<br />

The xSeries 345 includes eight front-accessible bays. The top right slim-line bay contains a slim-line 3.5in diskette drive and the top left slim-line bay contains a<br />

slim-line CD-ROM. Six slim-line, hot-swap HDD bays are located in the center of the front of the chassis.<br />

The system contains a DASD backplane supporting six hot-swap, SCA-2-compliant HDD bays. The backplane is connected to one of the connectors of the<br />

integrated Ultra320 SCSI controller through a 16-bit (nonterminated) LVD SCSI cable. In RAID configurations using ServeRAID-5i, no cable is required and both<br />

channels of the integrated controller are managed by ServeRAID-5i. Internal RAID configurations using ServeRAID-4Mx or -4Lx require optional 30in<br />

nonterminated Single-drop Internal LVD Ultra160 SCSI Cable (P/N 71P8995).<br />

External SCSI device attachment is facilitated by a dedicated 0.8mm VHDCI port on the rear of the system chassis, which is connected to the second channel of<br />

the integrated controller. If ServeRAID-5i is installed, supported tape drives that can be installed in an external tape enclosure are limited (see Tape Options<br />

section). External tape enclosures are also supported by installing PCI Wide Ultra160 SCSI Adapter (P/N 19K4646).<br />

The 24x-10x CD-ROM is connected to the IDE port through an interposer card.<br />

RDIMM 4<br />

fan 3<br />

fan 7<br />

xSeries 345 Memory<br />

Part<br />

Number<br />

Memory Description 1<br />

33L5037 256MB DDR PC2100 ECC RDIMM<br />

33L5038 512MB DDR PC2100 ECC RDIMM<br />

33L5039 1GB DDR PC2100 ECC RDIMM<br />

33L5040 2GB DDR PC2100 ECC RDIMM 2<br />

1. Due to two-way interleaving, installation of memory options in matched pairs is<br />

required. Install first two RDIMMs in sockets one and two and the second set in sockets<br />

three and four (refer to planar diagram).<br />

2. Due to thermal requirements associated with optional 2GB DDR PC2100 ECC<br />

RDIMM, 350w Hot-swap Power Supply Upgrade (P/N 59P4057) must be installed to<br />

support either one or two pairs of this RDIMM for 400MHz FSB models and 533MHz<br />

FSB models with 2.67 or 2.8GHz processors. The power supply upgrade includes a hotswap<br />

power supply that provides N+N power redundancy and three additional fans that<br />

provide redundant cooling. 533MHz FSB models for 3.06GHz processors ship standard<br />

with eight fans, but power supply redundancy using 514w Hot-swap Power Supply<br />

Upgrade (P/N 74P4965) is required to support 2GB RDIMMs.<br />

RDIMM 3<br />

CPU 1 CPU 2<br />

RDIMM 2<br />

fan 4<br />

fan 8<br />

RDIMM 1<br />

Total System<br />

Memory1 512MB<br />

(2 x 256MB)<br />

256MB<br />

(33L5037)<br />

For additional information regarding internal cabling, refer to Appendix F: Internal Cabling Overview.<br />

Quantity of RDIMMs Added<br />

512MB<br />

(33L5038)<br />

1GB<br />

(33L5039)<br />

2GB<br />

(33L5040)<br />

1GB 2 - - -<br />

1.5GB - 2 - -<br />

2.5GB - - 2 -<br />

3GB2 - 2 2 -<br />

4GB 2<br />

- - 4 -<br />

5GB2 - 2 - 2<br />

6GB 2<br />

- - 2 2<br />

8GB2 - - - 4<br />

This table does not represent all possible memory configurations. Memory modules may vary in price<br />

per MB. Selection of smaller RDIMMs may provide a more cost-effective alternative to using larger<br />

RDIMMs.<br />

1. Network operating systems may limit the maximum amount of addressable memory. See operating<br />

system specifications for further information.<br />

2. Requires replacing the standard RDIMMs.<br />

xSeries 345 Internal SCSI Cabling

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!