214<br />

Simple: two Rack PDUs<br />

(two circuits, 14 outlets)<br />

(2)<br />

Rack<br />

Cabinet<br />

2-bays per compartment<br />

(9306)<br />

Rack<br />

PDU<br />

Rack<br />

PDU<br />

Front-end<br />

PDU<br />

Rack<br />

PDU<br />

Front-end<br />

PDU<br />

Rack<br />

PDU<br />

P<br />

D<br />

U<br />

P<br />

D<br />

U<br />

Notes: Refer to notes on previous page.<br />

Rack PDU<br />

7 outlets - C13<br />

1 inlet - C20<br />

Typical Rack Power Configurations<br />

Rack Rules and PDU Capacities<br />

NetBAY and DPI PDUs cannot be mixed in the same side-wall compartment.<br />

DPI Rack PDUs can be cabled to NetBAY Front-end PDUs.<br />

PDUs/Rack Standard Enterprise<br />

9306-<br />

250<br />

9306-<br />

420,421<br />

9308<br />

2-bay 2-bay 2-bay 3-bay 4-bay<br />

Rack PDUs 4 8 8 8 12<br />

Dual-cord PDUs 3 3 3 3 3<br />

Front-end PDUs 2 4 2 4 4<br />

Total PDUs 4 12 8 12 16<br />

Side-wall Compartment Configurations<br />

2-bays per compartment<br />

(9308)<br />

Rack<br />

PDU<br />

Rack<br />

PDU<br />

Front-end<br />

PDU<br />

Rack<br />

PDU<br />

Simple: three Rack PDUs<br />

and one Front-end PDU<br />

(single circuit, 21 outlets)<br />

(5)<br />

Rack<br />

Cabinet P<br />

D<br />

U<br />

P<br />

D<br />

U<br />

F<br />

E<br />

P<br />

D<br />

U<br />

Standard Racks<br />

9306-420, 421<br />

9306-250<br />

U<br />

A B<br />

3-bays per compartment<br />

(9308)<br />

Front-end<br />

PDU<br />

Front-end<br />

PDU<br />

(4)<br />

Front-end PDU<br />

3 outlets - C19<br />

1 inlet - hardwired<br />

A<br />

C<br />

E<br />

Rack<br />

PDU<br />

Rack<br />

PDU<br />

Rack<br />

PDU<br />

Rack<br />

PDU<br />

U<br />

Redundant: six Rack PDUs<br />

and two Front-end PDUs (dual<br />

circuit, 42 outlets)<br />

P<br />

D<br />

U<br />

P<br />

D<br />

U<br />

F<br />

E<br />

P<br />

D<br />

U<br />

B<br />

D<br />

F<br />

(5)<br />

4-bays per compartment<br />

(9308)<br />

Rack<br />

PDU<br />

Rack<br />

PDU<br />

Rack<br />

PDU<br />

Rack<br />

PDU<br />

Rack<br />

Cabinet<br />

Enterprise Racks<br />

9308-42P, X, S, E<br />

A<br />

(4)<br />

C<br />

Rack<br />

PDU<br />

Rack<br />

PDU<br />

Front-end<br />

PDU<br />

Front-end<br />

PDU<br />

P<br />

D<br />

U<br />

P<br />

D<br />

U<br />

F<br />

E<br />

P<br />

D<br />

U<br />

U<br />

B<br />

D

Hooray! Your file is uploaded and ready to be published.