36<br />
Part<br />
Number<br />
Description RPM Height<br />
Hot-swap Models Nonhot-swap Models<br />
Bays<br />
Supported 3<br />
Maximum<br />
Quantity<br />
Bays<br />
Supported<br />
Maximum<br />
Quantity<br />
IDE HDDs1 22P7157 40GB 7200rpm ATA-100 (EIDE) HDD 7200 SL - - 4 ... 7 3<br />
09N4226 80GB 7200rpm ATA-100 (EIDE) HDD 7200 SL - - 4 ... 7 3<br />
09N4231 120GB 7200rpm ATA-100 (EIDE) HDD<br />
Nonhot-swap Ultra160 SCSI HDDs<br />
7200 SL - - 4 ... 7 3<br />
2<br />
06P5750 18.2GB 10Krpm Ultra160 SCSI SL HDD 10000 SL 4 1 4 ... 7 4<br />
06P5751 36.4GB 10Krpm Ultra160 SCSI SL HDD 10000 SL 4 1 4 ... 7 4<br />
06P5752 73.4GB 10Krpm Ultra160 SCSI SL HDD 10000 SL 4 1 4 ... 7 4<br />
06P5765 18.2GB 15Krpm Ultra160 SCSI SL HDD 15000 SL 4 1 4 ... 7 4<br />
06P5766 36.4GB 15Krpm Ultra160 SCSI SL HDD<br />
2, 3<br />
Nonhot-swap Ultra320 HDDs<br />
15000 SL 4 1 4 ... 7 4<br />
32P0723 36.4GB 10Krpm Ultra320 SCSI HDD 10000 SL 4 1 4 ... 7 4<br />
32P0724 73.4GB 10Krpm Ultra320 SCSI HDD 10000 SL 4 1 4 ... 7 4<br />
32P0725 146.8GB 10Krpm Ultra320 SCSI HDD<br />
Hot-swap Ultra160 SCSI HDDs<br />
10000 SL 4 1 4 ... 7 4<br />
4<br />
06P5754 18.2GB 10Krpm Ultra160 SCSI Hot-Swap SL HDD 10000 SL 5 ... 7 3 - -<br />
06P5755 36.4GB 10Krpm Ultra160 SCSI Hot-Swap SL HDD 10000 SL 5 ... 7 3 - -<br />
06P5756 73.4GB 10Krpm Ultra160 SCSI Hot-Swap SL HDD 10000 SL 5 ... 7 3 - -<br />
06P5767 18.2GB 15Krpm Ultra160 SCSI Hot-Swap SL HDD 15000 SL 5 ... 7 3 - -<br />
06P5768 36.4GB 15Krpm Ultra160 SCSI Hot-Swap SL HDD 15000 SL 5 ... 7 3 - -<br />
Optical Devices<br />
Bays<br />
Supported<br />
22P6950 16x Max RAM-Read DVD-ROM Drive5, 6 1, 2<br />
10K3782 48x-20x CD-ROM Black Internal IDE Drive5 1, 2<br />
22P6970 Multi-Burner5, 6 1, 2<br />
22P6997 48x-24x-48x CD-RW Drive 5<br />
1, 2<br />
External Storage Expansion Units7 Form Factor<br />
35311RU EXP300 Storage Expansion Unit 8<br />
Rack (3U)<br />
09N7296 EXP300 Rack-to-Tower Conversion Kit -<br />
1. The xSeries 205 EIDE controllers support a maximum of four IDE devices per machine including CD-ROM drives, hard disk drives and IDE tape drives.<br />
2. Nonhot-swap HDDs are supported in bays 4 ... 7 of nonhot-swap models and in bay four of hot-swap models. Nonhot-swap HDDs are not supported on the same SCSI bus as the hotswap<br />
backplane in hot-swap models.<br />
3. Ultra320 HDDs are supported, but performance is limited to the Ultra160 speed of the SCSI controller.<br />
4. Hot-swap HDDs are supported in bays 5 ... 7 of hot-swap models. Bay four supports nonhot-swap HDDs only. Nonhot-swap HDDs are not supported on the same SCSI bus as the hotswap<br />
backplane in hot-swap models.<br />
5. Either replace the standard CD-ROM or install in the available media bay. A two-drop IDE cable is included with the optional optical drive (same cable is standard in the system). If installing<br />
as an additional device, connect the cable to each optical device and the IDE connector on the system board. Configure the optional device as a master using the preset configuration if<br />
replacing the standard device or as a slave if installed as an additional device.<br />
6. Audio not supported for DVD-ROM drives. The drive provides data input/output only.<br />
7. Not supported by the onboard SCSI controller. Select an optional SCSI controller then refer to Appendix D: Cables - Storage Units - Controllers to confirm the controller supports the desired<br />
External Storage Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific expansion unit section.<br />
8. EXP300 includes a single 2m Ultra2 SCSI cable and dual hot-swap 500w redundant power supplies, each with its own power cord. To convert an EXP300 to a tower form factor, EXP300<br />