Updated 07/01/03<br />

Part<br />

Number<br />

Description RPM Height<br />

Bays<br />

Supported<br />

Maximum<br />

Quantity<br />

06P5761 2Gb<strong>ps</strong> FC 36.4GB/10K Drive 10,000 SL 1 ... 14 14<br />

06P5762 2Gb<strong>ps</strong> FC 73.4GB/10K Drive 10,000 SL 1 ... 14 14<br />

32P0765 146.8GB Fibre Channel Disk Drive Module 10,000 SL 1 ... 14 14<br />

06P5771 2Gb<strong>ps</strong> FC 18.2GB/15K Drive 15,000 SL 1 ... 14 14<br />

06P5772 2Gb<strong>ps</strong> FC 36.4GB/15K Drive 15,000 SL 1 ... 14 14<br />

32P0768 73.4GB/15K Disk Module 15,000 SL 1 ... 14 14<br />

External Storage Expansion Units Form Factor<br />

17401RU FAStT EXP700 Storage Expansion Unit1 Rack (3U)<br />

1. The FAStT EXP700 includes two hot-swap, 400w auto-ranging redundant power supplies, each with its own power cord.<br />

Out<br />

In<br />

FAStT EXP700 1<br />

17401RU<br />

Bay 1<br />

Bay 2<br />

Bay 3<br />

Bay 4<br />

Bay 5<br />

Bay 6<br />

Loop A<br />

Bay 7<br />

Bay 8<br />

Loop B<br />

Bay 9<br />

Bay 10<br />

Bay 11<br />

Bay 12<br />

Fibre Channel<br />

Connectors 2<br />

Bay 13<br />

Bay 14<br />

IN = primary or secondary (redundant) connection from FAStT700 Storage<br />

Server or previous FAStT EXP700 expansion unit daisy-chained from the<br />

storage server<br />

OUT = primary or secondary (redundant) connection to additional FAStT<br />

EXP700 expansion units<br />

1. Housed in a 19in rack-mountable drawer and shi<strong>ps</strong> standard with redundant power supplies<br />

and two power cables requiring separate power sources. Requires an <strong>IBM</strong> industry standard<br />

19in rack, EIA-310D with a minimum depth of 24in (711.2mm). Select optional storage<br />

controllers and external cables, which are not included with the FAStT storage server or<br />

external enclosure, using the Fibre Device Ports Reference.<br />

2. SFP Modules are not included. Either Fibre Channel long or short-wave SFP Modules<br />

(P/N 19K1272 or 19K1271 respectively) may be used.<br />

For the latest product & technical information, refer to the Information Sources on pages 2 & 3.<br />

Out<br />

In<br />

195<br />

<strong>IBM</strong> FAStT EXP700