Updated 07/01/03<br />

09N4300<br />

4Ux20D Tower-to-Rack Kit<br />

59P4817<br />

4U Extended Depth<br />

Tower-to-Rack Conversion Kit<br />

Server System Rack Alternatives<br />

Conversion Kits Standard Racks1 Enterprise<br />

Racks1 59P4211<br />

5Ux24D Tower-to-Rack Kit iII<br />

32P1474<br />

7Ux26D Tower-to-Rack Kit<br />

37L6859<br />

8Ux24D Tower-to-Rack Kit<br />

Servers<br />

xSeries 205 2<br />

X X X X X X X<br />

xSeries 2252 X X X X X X X<br />

xSeries 235 X X X X X X X<br />

xSeries 255 X X X X X X X<br />

xSeries 305 3<br />

X X X X X X<br />

xseries 335 X X X X X X<br />

xSeries 345 4<br />

X X X X X X<br />

xSeries 360 X X X X X X<br />

xSeries 440 X X X X X X<br />

xSeries 445 X X X X X X<br />

xSeries 450 X X X X X X<br />

BladeCenter X X X X X X<br />

1. See the first page of Rack Cabinets and Options section for additional information concerning <strong>IBM</strong> rack-supported devices.<br />

2. Rack installation requires appropriate conversion kit.<br />

3. Blank filler panels (P/N 94G6670) should be placed on the front of any unused rack space to aid proper airflow through the system units. If non-<strong>IBM</strong> racks<br />

are used, assure that both the front and rear doors offer a minimum of 45% open area uniformly distributed and in line with the installed servers. A clearance<br />

of at least 51mm (2in) must be maintained between the front door and the system unit’s front bezel. The rear door must maintain the same or greater<br />

clearance. Nonrack installations are not supported.<br />

4. If installed in older <strong>IBM</strong> racks, the server should not be installed behind a glass door that blocks air flow. Remove the glass door or replace with an optional<br />

perforated door. To order a rack extension kit for withdrawn <strong>IBM</strong> racks, visit the Options Continuation Program Website at www.pc.ibm.com/ww/ocp.<br />

37L6860<br />

8Ux24D Rack-to-Tower Kit<br />

9306-110<br />

NetBAY11<br />

9306-250<br />

NetBAY25SR<br />

9306-420<br />

NetBAY42SR<br />

9306-421<br />

NetBAY 42SX<br />

9308-42S<br />

NetBAY42ER<br />

9308-42E<br />

NetBAY42EX<br />

For the latest product & technical information, refer to the Information Sources on pages 2 & 3.<br />