28. xSeries 335 includes new interconnect cabling options available through the C2T Interconnect cable chaining connection. One integrated RS-485 port is available for connecting the<br />
integrated ISMP to an optional RSA when that system is used as a system management interconnect network focal point. Interconnect network connections are then established through the<br />
cable chaining connection for additional x335 systems. The external AC power supply provided with RSA is not required. See Rack Cabinets and Options or system sections for additional<br />
information regarding console connectivity.<br />
Updated 07/01/03<br />
System Management Functional Comparison<br />
Feature/Function<br />
Onboard<br />
ASMP ISMP<br />
PCI Adapter<br />
1<br />
ASMA 2<br />
Monitoring & Alerting<br />
2, 3, 4<br />
RSA<br />
Automatic server shutdown/restart yes yes yes yes<br />
Environmental monitors (temperature, voltage) yes yes yes yes<br />
Interface with Light Path Diagnostics yes yes yes yes5 PFA on system components (fans, power<br />
supplies, memory, etc.)<br />
yes yes6 yes yes<br />
Post, loader, OS timeouts<br />
Alert Mechanisms<br />
yes yes yes yes<br />
Pager (numeric/alphanumeric) 7 yes no yes yes<br />
Alert on LAN 2 8<br />
no yes 11<br />
no no<br />
Director via LAN yes10 yes 10<br />
yes yes<br />
Director via serial 9<br />
yes no yes yes<br />
E-mail no no no yes<br />
Generate SNMP tra<strong>ps</strong> yes10 yes10 Management<br />
yes yes<br />
Remote BIOS and SP firmware update12 yes yes13 yes yes14 Remote GUI-mode control no no no<br />
5, 15<br />
yes<br />
Remote text-mode control yes no no yes<br />
Remote POST and diagnostics12 yes no yes yes16, 17<br />
View status logs yes no yes yes<br />
View vital product data yes no yes yes<br />
Capture Windows blue screens no no no yes15 View SP configuration no no yes yes<br />
Set SP configuration no no no yes14 Save and restore SP configuration no no no yes 15<br />
Restart SP<br />
Connectivity & Cabling<br />
no no yes yes<br />
<strong>IBM</strong> Director18 yes yes yes yes<br />
ANSI terminal 9<br />
yes no yes yes<br />
Telnet yes 19 no yes yes<br />
Web interface yes19 no yes yes<br />
10/100 Ethernet yes20 yes11 yes yes<br />
DHCP no no no yes<br />
DNS no no no yes<br />
PPP7 no no no yes<br />
Dedicated serial port yes no dual21 yes<br />
Shared serial port yes no dual 21<br />
no<br />
Redundant external power no no yes yes<br />
1. This table is correct only for ISMP firmware v1.02 or newer. Systems shipped after January 1, 2002 include v1.02 firmware. Firmware updates are available on the<br />
Web at the URL www.pc.ibm.com/qtechinfo/MIGR-4WEP53.html.<br />
2. When either RSA or ASMA are integrated as a standard adapter in an xSeries server (e.g., x360 or x440), the two interconnect cables, external power supply and<br />
power cords provided with the optional packages are not included.<br />
3. When an optional RSA (P/N 09N7585) is installed in a system with standard ISMP, the optional adapter manages the onboard service processor and assumes all<br />
communications functionality.<br />
4. When an optional RSA (P/N 09N7585) is installed in a system with standard ASMP, the optional adapter serves only as an Ethernet and interconnect gateway. The<br />
onboard ASMP provides all service processor data. An external Cat5 connection is required.<br />
5. Not available when RSA is added as an option to systems with standard ASMP (e.g., x330).<br />
6. Performs monitoring capability only. Automated alerting available through <strong>IBM</strong> Director only.<br />
7. Requires customer-supplied external modem.<br />
8. Only available with <strong>IBM</strong> Director version 3.1 or newer.<br />
9. Requires customer-supplied external modem or null-modem cable.<br />
10. The specified alerting mechanisms may be configured, but sending such alerts to their destination requires connection through an RSA or ASMA either within<br />
the local machine or via the interconnect network.<br />
11. This functionality is only available on xSeries 235 and 255 servers, which include ISMP upgraded with a dedicated gigabit Ethernet processor.<br />
12. Requires an out-of-band connection such as a serial, Ethernet or ASM interconnect network (out-of-band connections bypass the NOS and are established<br />
even when the NOS is not functioning).<br />
13. Only updates to the the service processor firmwware are possible. BIOS firmware updates are not available when using ISMP.<br />
14. Only available through the Web interface, connected via Ethernet or PPP.<br />
15. Only available through the Web or Telnet interface, via an Ethernet connection.<br />
16. Not available via interconnect network.<br />
17. Not available on systems without standard system management to which an optional RSA has been added (e.g., x220).<br />
18. Connection to <strong>IBM</strong> Director allows use of all management and alerting functionality (except save and restore configuration file) via an active in-band, out-ofband<br />
or interconnect network connection.<br />
19. Connection using Telnet, Web interface or Ethernet is available via an RSA or ASMA through the interconnect network.<br />
20. Requires interconnection of integrated service processor to optional ASMA or RSA using an Interconnect Cable Kit (P/N 03K9309).<br />
21. Requires the use of the included serial port splitter cable.<br />
For the latest product & technical information, refer to the Information Sources on pages 2 & 3.<br />