28. xSeries 335 includes new interconnect cabling options available through the C2T Interconnect cable chaining connection. One integrated RS-485 port is available for connecting the<br />

integrated ISMP to an optional RSA when that system is used as a system management interconnect network focal point. Interconnect network connections are then established through the<br />

cable chaining connection for additional x335 systems. The external AC power supply provided with RSA is not required. See Rack Cabinets and Options or system sections for additional<br />

information regarding console connectivity.<br />

Updated 07/01/03<br />

System Management Functional Comparison<br />

Feature/Function<br />

Onboard<br />

ASMP ISMP<br />

PCI Adapter<br />

1<br />

ASMA 2<br />

Monitoring & Alerting<br />

2, 3, 4<br />

RSA<br />

Automatic server shutdown/restart yes yes yes yes<br />

Environmental monitors (temperature, voltage) yes yes yes yes<br />

Interface with Light Path Diagnostics yes yes yes yes5 PFA on system components (fans, power<br />

supplies, memory, etc.)<br />

yes yes6 yes yes<br />

Post, loader, OS timeouts<br />

Alert Mechanisms<br />

yes yes yes yes<br />

Pager (numeric/alphanumeric) 7 yes no yes yes<br />

Alert on LAN 2 8<br />

no yes 11<br />

no no<br />

Director via LAN yes10 yes 10<br />

yes yes<br />

Director via serial 9<br />

yes no yes yes<br />

E-mail no no no yes<br />

Generate SNMP tra<strong>ps</strong> yes10 yes10 Management<br />

yes yes<br />

Remote BIOS and SP firmware update12 yes yes13 yes yes14 Remote GUI-mode control no no no<br />

5, 15<br />

yes<br />

Remote text-mode control yes no no yes<br />

Remote POST and diagnostics12 yes no yes yes16, 17<br />

View status logs yes no yes yes<br />

View vital product data yes no yes yes<br />

Capture Windows blue screens no no no yes15 View SP configuration no no yes yes<br />

Set SP configuration no no no yes14 Save and restore SP configuration no no no yes 15<br />

Restart SP<br />

Connectivity & Cabling<br />

no no yes yes<br />

<strong>IBM</strong> Director18 yes yes yes yes<br />

ANSI terminal 9<br />

yes no yes yes<br />

Telnet yes 19 no yes yes<br />

Web interface yes19 no yes yes<br />

10/100 Ethernet yes20 yes11 yes yes<br />

DHCP no no no yes<br />

DNS no no no yes<br />

PPP7 no no no yes<br />

Dedicated serial port yes no dual21 yes<br />

Shared serial port yes no dual 21<br />

no<br />

Redundant external power no no yes yes<br />

1. This table is correct only for ISMP firmware v1.02 or newer. Systems shipped after January 1, 2002 include v1.02 firmware. Firmware updates are available on the<br />

Web at the URL www.pc.ibm.com/qtechinfo/MIGR-4WEP53.html.<br />

2. When either RSA or ASMA are integrated as a standard adapter in an xSeries server (e.g., x360 or x440), the two interconnect cables, external power supply and<br />

power cords provided with the optional packages are not included.<br />

3. When an optional RSA (P/N 09N7585) is installed in a system with standard ISMP, the optional adapter manages the onboard service processor and assumes all<br />

communications functionality.<br />

4. When an optional RSA (P/N 09N7585) is installed in a system with standard ASMP, the optional adapter serves only as an Ethernet and interconnect gateway. The<br />

onboard ASMP provides all service processor data. An external Cat5 connection is required.<br />

5. Not available when RSA is added as an option to systems with standard ASMP (e.g., x330).<br />

6. Performs monitoring capability only. Automated alerting available through <strong>IBM</strong> Director only.<br />

7. Requires customer-supplied external modem.<br />

8. Only available with <strong>IBM</strong> Director version 3.1 or newer.<br />

9. Requires customer-supplied external modem or null-modem cable.<br />

10. The specified alerting mechanisms may be configured, but sending such alerts to their destination requires connection through an RSA or ASMA either within<br />

the local machine or via the interconnect network.<br />

11. This functionality is only available on xSeries 235 and 255 servers, which include ISMP upgraded with a dedicated gigabit Ethernet processor.<br />

12. Requires an out-of-band connection such as a serial, Ethernet or ASM interconnect network (out-of-band connections bypass the NOS and are established<br />

even when the NOS is not functioning).<br />

13. Only updates to the the service processor firmwware are possible. BIOS firmware updates are not available when using ISMP.<br />

14. Only available through the Web interface, connected via Ethernet or PPP.<br />

15. Only available through the Web or Telnet interface, via an Ethernet connection.<br />

16. Not available via interconnect network.<br />

17. Not available on systems without standard system management to which an optional RSA has been added (e.g., x220).<br />

18. Connection to <strong>IBM</strong> Director allows use of all management and alerting functionality (except save and restore configuration file) via an active in-band, out-ofband<br />

or interconnect network connection.<br />

19. Connection using Telnet, Web interface or Ethernet is available via an RSA or ASMA through the interconnect network.<br />

20. Requires interconnection of integrated service processor to optional ASMA or RSA using an Interconnect Cable Kit (P/N 03K9309).<br />

21. Requires the use of the included serial port splitter cable.<br />

For the latest product & technical information, refer to the Information Sources on pages 2 & 3.<br />