20. This channel may be connected to either a supported tape drive or the Ultra320 3-pack Kit (P/N 33P2751) installed in the media bays. If no internal connection is established, the 0.8mm<br />

VHDCI external SCSI port can be enabled by installing External SCSI Interface Kit (P/N 32P8164).<br />

21. Termination is provided by the one-drop cable included with the tape option or by the optional hot-swap backplane when the Ultra320 3-pack Kit is installed, which includes a<br />

nonterminated cable.<br />

22. Optional 30in nonterminated Single-drop Internal LVD Ultra160 SCSI Cable (P/N 71P8995) is required to connect the hot-swap backplane to ServeRAID-4H, -4Mx or -4Lx. ServeRAID-5i<br />

does not require a cable.<br />

23. If the optional Ultra320 3-pack Kit (P/N 33P2751) is installed in the media bays, the cable that shi<strong>ps</strong> with the option is used to connect to ServeRAID-4H, -4Mx or -4Lx or to the integrated<br />

controller if ServeRAID 5i is installed.<br />

24. An optional 6-pack Ultra320 Hot-swap Expansion Kit (P/N 32P8163) can be installed above the standard six hot-swap HDD bays and a full-high or half-high tape drive can be installed in<br />

the available media bays.<br />

25. SCSI RAID adapters are generally connected to the hot-swap backplane using the standard cable that connects the integrated storage controller. When the standard cable is used for<br />

RAID attachment, media bay attachment requires the 34in terminated SCSI cable provided standard with tape drive options. Attachment of optional 6-pack Ultra320 Hot-swap Expansion Kit<br />

(P/N 32P8163) connects to a RAID adapter using the cable that shi<strong>ps</strong> with the option.<br />

26. If ServeRAID-5i is installed, the standard cable that connects the backplane to the integrated controller remains connected. If ServeRAID-4Mx or -4Lx support the internal HDD<br />

backplane, then optional 30in nonterminated Single-drop Internal LVD Ultra160 SCSI Cable (P/N 71P8995) is required.<br />

27. Attachment of PCI RAID controllers to the internal hot-swap backplane is not supported. Mirroring of the internal HDDs is supported through the integrated controller (HDDs must be<br />

matched).<br />

For additional information, refer to the Internal SCSI Cabling and Tape Options sections for each system or to Appendix D: SCSI Cables - Storage Units -<br />