FAStT200 HA Storage Server (P/N 35422RU)<br />

GBIC Port 10/100 Ethernet Port<br />

RS-232<br />

Hot-swap Fan Hot-swap Power Hot-swap Fan<br />

GBIC Port<br />

• Contains two hot-plug RAID controllers. Each controller provides a single<br />

host Fibre Channel arbitrated loop and a single storage Fibre Channel<br />

arbitrated loop.<br />

• Integrated 10/100Mb<strong>ps</strong> Ethernet connector and RS-232 service support port.<br />

• Performance optimized for 60 HDDs - supports optional FAStT EXP500<br />

Storage Expansion Units (P/N 35601RU).<br />

• Two hot-swap 350W auto-ranging, redundant power supplies.<br />

• Redundant fans: two hot-swap, dual-fan units.<br />

• LED indicators on all critical components warn of faults, over-temperature,<br />

and other abnormalities.<br />

• Ten drive bays - supports slim-line or half-high Fibre Channel hot-swap<br />

HDDs.<br />

• Height is 3U (1U=1.75in or 44.45mm).<br />

• Supports long- and short-wave connections. Requires optional GBICs for<br />

each connection. GBICs not included.<br />

SAN Fibre Channel Switch, 8-port (P/N 3534F08)<br />

• Provides 2Gb per second port-to-port throughput with autosensing<br />

capability for connecting to 1Gb per second host servers, storage and<br />

switches with full operability.<br />

• Contained in a 1U mechanical.<br />

• Includes a comprehensive set of management tools that support a Web<br />

browser interface.<br />

• Four short-wave SFP Modules (optical transceivers) are standard.<br />

• Supports up to 192 ports in a single 42U rack (scalable to 239 switches<br />

maximum).<br />

• Additional related options include F08 Full Fabric Activation (P/N 18P5060),<br />

Performance Bundle Activation (P/N 18P4405), Fabric Manager Version 4.0<br />

(P/N 17P7180) and F08 Advanced Security Activation (P/N 18P4411).<br />

SAN Fibre Channel Switch, 16-port (P/N 2109F16)<br />

• Provides 2Gb per second port-to-port throughput with autosensing<br />

capability for connecting to 1Gb per second host servers, storage and<br />

switches with full operability.<br />

• Contained in a 1U mechanical, requiring half the rack space of the 1Gb<br />

16-port switch.<br />

• Up to four Inter-Switch Links can be trunked for throughput of up to 8Gb per<br />

second.<br />

• Includes a comprehensive set of management tools that support a Web<br />

browser interface.<br />

• Eight short-wave SFP Modules (optical transceivers) are standard.<br />

• Built-in redundancy with no single points of failure.<br />

• Supports up to 384 ports in a single 42U rack (scalable to 239 switches<br />

maximum).<br />

• Shi<strong>ps</strong> with one hot-swap 126W power supply. and supports an optional<br />

redundant power supply (P/N 18P3576).<br />

• Additional related options include Remote Switch Activation (P/N 18P3579),<br />

Extended Fabric Activation (P/N 18P3580), F16 Performance Bundle<br />

Activation (P/N 18P3590), Fabric Manager Version 4.0 (F16) (P/N 18P7182)<br />

and F16 Advanced Security Activation (P/N 18P3596). Power cords for<br />

nonrack installation are available by country.<br />

Updated 07/01/03<br />

LC-SC Fibre Channel Adapter Cable (P/N 19K1250)<br />

• Nine-inch adapter cable used to connect 1Gb cable or devices to 2Gb<br />

cable or devices.<br />

• To plug into a FAStT Host Adapter integrated GBIC (or any short-wave<br />

GBIC), remove the black ca<strong>ps</strong> from the 1Gb male SC connector (B).<br />

• To attach LC-LC cable, remove the white ca<strong>ps</strong> from the 2Gb female LC<br />

connector (A) and insert the male connector of the LC-LC cable.<br />

Host SFP<br />

Module<br />

ports<br />

A (female LC) B (male SC)<br />

FAStT900 Storage Server (P/N 174290U)<br />

Mini hub<br />

Expansion bays for<br />

additional mini hubs<br />

Mini hub<br />

Power supplies<br />

• Dual high-performance RAID controller cards supporting up to 772MB/sec of<br />

throughput.<br />

• Operates at 1Gb or 2Gb (autosensing).<br />

• Dual 175w auto-ranging, hot-swap, redundant power supplies.<br />

• Attach directly to FC2-133 Host Bus Adapter (P/N 24P0960) with short-wave<br />

cables and SFP Modules or indirectly through the SAN Fibre Channel<br />

Switch, 16-port (P/N 2109F16) or TotalStorage SAN Switch F08, 8-port<br />

(P/N 3534F08) using LC-LC cables from cable group D2 or E with<br />

corresponding SFP Modules.<br />

• Height is 4U (1U = 1.75in or 44.45mm).<br />

• For optimum performance no more than two FAStT900 Storage Servers<br />

(P/N 174290U) should be attached to a a single Fibre Channel switch.<br />

• Includes four FAStT700 Mini Hubs (P/N 19K1269), two host-side and two<br />

storage drive-side.<br />

• Each controller is equipped with 1GB of cache (2GB total).<br />

• All connections to FAStT700 Mini Hubs require the use of SFP Modules,<br />

which are not included.<br />

FAStT600 Storage Server (P/N 172260U)<br />

Ethernet Ethernet<br />

Host port 2<br />

Expansion port<br />

Host port 2<br />

Host port 1<br />

AC power<br />

connector<br />

Serial port Serial port<br />

Host port 1<br />

AC power<br />

switch<br />

Server ID<br />

switch<br />

AC power<br />

connector<br />

Drive SFP<br />

Module<br />

ports<br />

Expansion port<br />

AC power<br />

switch<br />

• Compact 3U rack-mountable enclosure.<br />

• Dual 2Gb<strong>ps</strong> RAID controllers with 256MB cache (128MB per controller)<br />

supporting up to 400MB/s of throughput.<br />

• Fourteen Fibre Channel HDD bays (over 2TB of storage capacity).<br />

• Redundant hot-swap 390w power supplies and cooling fans.<br />

• Supports two FAStT EXP700 Expansion Units via EXP700 attachment<br />

features.<br />

• Supports RAID types 0, 1, 3, 5, 10.<br />

• Four host ports standard (two per controller), attaching to either Fibre<br />

Channel switched fabrics or host servers.<br />

• Short and long-wave Fibre Channel host attachment.<br />

• FAStT Storage Manager v8.33 with upgrade capability for eight storage<br />

partitions.<br />

• All host and expansion connections require SFP Modules (not included).<br />

For the latest product & technical information, refer to the Information Sources on pages 2 & 3.<br />

201<br />

Fibre Channel Overview