196<br />

1.<br />

2.<br />

3.<br />

4.<br />

FC2-133 Host<br />

Bus Adapter 1<br />

FC2-133 Host<br />

Bus Adapter 1<br />

FC2-133 Host<br />

Bus Adapter 1<br />

FC2-133 Host<br />

Bus Adapter 1<br />

FC2-133 Host<br />

Bus Adapter 1<br />

Fibre / Fibre Configuration Examples<br />

FAStT EXP700 with FAStT700 Fibre Channel Storage Server<br />

Note: The following sample configurations are for illustration only and may not be suitable for any<br />

specific customer installation. Contact your <strong>IBM</strong> Business Partner or <strong>IBM</strong> Marketing Representative<br />

for assistance with your specific configuration requirements.<br />

FAStT700 Storage Server<br />

(P/N 17421RU)<br />

FAStT700 Storage Server<br />

(P/N 17421RU)<br />

FAStT700 Storage Server<br />

(P/N 17421RU)<br />

FC2-133 Host<br />

Bus Adapter<br />

1 D2<br />

D2 or E<br />

SAN FC Switch<br />

(2109F16)<br />

FAStT700 Storage Server<br />

(P/N 17421RU)<br />

FC2-133 Host<br />

Bus Adapter 1<br />

FC2-133 Host<br />

Bus Adapter 1<br />

D2<br />

D2<br />

D2<br />

D2<br />

D2<br />

E<br />

D2<br />

SAN FC Switch 16-port<br />

(2109F16)<br />

D2 or E<br />

SAN FC Switch<br />

(2109F16) 2<br />

D2<br />

D2 or E<br />

1. FC2-133 Host Bus Adapter (P/N 24P0960) includes an integrated short-wave SFF Module, supporting short-wave connections only.<br />

2. Buffering the long-wave optic cable expanse with a second switch or hub at the remote storage location is required to requalify the signal.<br />

• P = primary path, S = secondary (redundant) path.<br />

• Shaded boxes represent separate hosts.<br />

• Cable grou<strong>ps</strong> are represented by letters.<br />

• A maximum of 224 external storage HDDs are supported through a maximum of eight enclosures in a redundant loop (cable pair). The maximum number of enclosures<br />

supported is 16. A maximum of two loo<strong>ps</strong> running in redundant mode are supported with four drive-side mini hubs.<br />

• The number of servers that can be used in configurations with managed hubs or Fibre Channel switches are dependent on partitioning restrictions of the management system<br />

or cluster software.<br />

• An optional short- or long-wave SFP Module is required for all FAStT EXP700 storage connections. FAStT700 and 2Gb Fibre Channel switch connections require SFP Modules.<br />

SFP Modules and adapter cables are not depicted in these diagrams. See device drawings at the end of this section for details.<br />

• For specific requirements concerning connections, refer to the Fibre Device Ports Reference or Fibre Interconnection Guidelines.<br />

Refer to the Supported Cable Grou<strong>ps</strong> chart following the FAStT 200 configuration examples for cable type definitions.<br />

P<br />

P<br />

P<br />

P<br />

D2<br />

D2<br />

D2<br />

D2<br />

D2<br />

D2<br />

D2<br />

D2<br />

P<br />

P<br />

P<br />

FAStT EXP700<br />

FAStT EXP700<br />

FAStT EXP700<br />

FAStT EXP700<br />

FAStT EXP700<br />

FAStT EXP700<br />

FAStT EXP700<br />

S<br />

S<br />

S<br />

S<br />

S<br />

S<br />

S