226<br />

Int’l Part<br />

Number<br />

United<br />

States<br />

Part<br />

Number<br />

Total<br />

Load<br />

(Watts)<br />

SU-700iNET<br />

94G4073<br />

SU-700NET<br />

94G3134<br />

Runtime<br />

Minutes<br />

SU-1000iNET<br />

94G4074<br />

SU-1000NET<br />

94G3135<br />

Runtime<br />

Minutes<br />

Total Configuration Runtime Estimator (time in minutes) 1<br />

Tower Rack Mount<br />

SU-1400iNET<br />

94G4075<br />

SU-1400NET<br />

94G3136<br />

Runtime<br />

Minutes<br />

SU-2200iNET<br />

94G4076<br />

SU-1400RMiB<br />

94G6675<br />

Not Available SU-1400RMB<br />

94G6674<br />

Runtime<br />

Minutes<br />

Runtime<br />

Minutes<br />

2U SU-1400RMiB<br />

32P1022<br />

2U SU-1400RMB<br />

32P1020<br />

Runtime<br />

Minutes<br />

SU-3000RMiB<br />

94G6677<br />

SU-3000RMB<br />

94G6676<br />

Runtime<br />

Minutes<br />

SU-5000RMiB<br />

37L6862<br />

SU-5000RMB<br />

37L6861<br />

Runtime<br />

Minutes<br />

200 22 38 62 130 45 45 104 240<br />

250 17 28 43 104 34 34 84 200<br />

300 12 22 34 85 25 25 70 166<br />

350 9 18 29 71 22 22 58 145<br />

400 7 14 23 65 18 18 52 125<br />

450 5 12 20 52 15 15 45 110<br />

500 - 11 18 43 13 13 38 97<br />

550 - 9 16 38 11 11 35 87<br />

600 - 8 13 34 10 10 31 76<br />

650 - 7 12 31 9 9 29 68<br />

700 - 6 11 28 8 8 26 63<br />

750 - - 10 25 8 8 24 59<br />

800 - - 9 23 7 7 22 55<br />

850 - - 8 21 7 7 20 51<br />

900 - - 7 19 6 6 18 47<br />

950 - - 6 18 5 5 17 43<br />

1000 - - - 17 - - 16 39<br />

1100 - - - 15 - - 14 34<br />

1200 - - - 13 - - 12 31<br />

1300 - - - 11 - - 10 28<br />

1400 - - - 9 - - 9 25<br />

1500 - - - 9 - - 8 22<br />

1600 - - - 8 - - 8 20<br />

1700 - - - - - - 7 18<br />

1800 - - - - - - - 17<br />

1900 - - - - - - - 14<br />

2000 - - - - - - - 12<br />

2100 - - - - - - - 11<br />

2200 - - - - - - 11<br />

2300 - - - - - - - 10<br />

2400 - - - - - - 10<br />

2500 - - - - - - - 9<br />

2600 - - - - - - 9<br />

2700 - - - - - - - 8<br />

2800 - - - - - - - 8<br />

1. Data provided by APC.<br />

Ste<strong>ps</strong>:<br />

1. Identify the devices contained in the configuration.<br />

2. Sum the load (watts) of all devices in the configuration. Use either Maximum Load for minimum runtime or Typical Load for typical runtime.<br />

3. Find the Total Configuration Load in the table above.<br />

4. Select the most appropriate UPS model to achieve the desired runtime.