02.11.2012 Views

IBM IntelliStation - ps-2

IBM IntelliStation - ps-2

IBM IntelliStation - ps-2

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

190<br />

1.<br />

2.<br />

3.<br />

4.<br />

FAStT FC-2 Host<br />

Bus Adapter 1<br />

FAStT FC-2 Host<br />

Bus Adapter 1<br />

FAStT FC-2 Host<br />

Bus Adapter 1<br />

FAStT FC-2 Host<br />

Bus Adapter 1<br />

FAStT FC-2 Host<br />

Bus Adapter 1<br />

Fibre / Fibre Configuration Examples<br />

FAStT EXP500 with FAStT700 Fibre Channel Storage Server<br />

Note: The following sample configurations are for illustration only and may not be suitable for any<br />

specific customer installation. Contact your <strong>IBM</strong> Business Partner or <strong>IBM</strong> Marketing Representative<br />

for assistance with your specific configuration requirements.<br />

FAStT700 Storage Server<br />

(P/N 17421RU)<br />

FAStT700 Storage Server<br />

(P/N 17421RU)<br />

FAStT700 Storage Server<br />

(P/N 17421RU)<br />

D2<br />

D2 or E<br />

FAStT FC-2 Host<br />

Bus Adapter<br />

1 SAN FC Switch<br />

(2109F16)<br />

FAStT700 Storage Server<br />

(P/N 17421RU)<br />

FAStT FC-2 Host<br />

Bus Adapter 1<br />

FAStT FC-2 Host<br />

Bus Adapter 1<br />

D2<br />

D2<br />

D2<br />

D2<br />

D2<br />

E<br />

D2<br />

SAN FC Switch 16-port<br />

(2109F16)<br />

D2 or E<br />

SAN FC Switch<br />

(2109F16) 3<br />

D2<br />

D2 or E<br />

D1 or D2 2<br />

1. FAStT FC-2 Host Bus Adapter (P/N 24P0960) includes an integrated short-wave SFF Module, supporting short-wave connections only.<br />

2. Fibre Channel connections to the FAStT EXP500 require GBICs. LC-LC Fibre Channel cable does not connect directly into a GBIC. LC-SC Fibre Channel Adapter Cable (P/N<br />

19K1250) is required. Use SC Fibre Channel cable for daisy-chaining FAStT EXP500 units (see the Supported Cable Grou<strong>ps</strong> chart for a list of SC cables).<br />

3. Buffering the long-wave optic cable expanse with a second switch or hub at the remote storage location is required to requalify the signal.<br />

• P = primary path, S = secondary (redundant) path<br />

• Shaded boxes represent separate hosts.<br />

• Cable grou<strong>ps</strong> are represented by letters.<br />

• Maximum of 220 external storage HDDs are supported through a maximum of 11 enclosures in each channel pair (22 enclosures total).<br />

• The number of servers that can be used in configurations with managed hubs or Fibre Channel switches are dependent on partitioning restrictions of the management system<br />

or cluster software.<br />

• An optional short- or long-wave GBIC is required for all FAStT500 EXP500 storage connections. FAStT700 and 2Gb FC switch connections require SFP Modules. LC-SC FC<br />

Adapter Cables are required to connect LC-LC FC cables to GBICs in FAStT EXP500 connections. GBICs, SFP Modules and adapter cables are not depicted in these diagrams.<br />

See device drawings at the end of this section for details.<br />

• For specific requirements concerning connections, refer to the Fibre Device Ports Reference or Fibre Interconnection Guidelines.<br />

Refer to the Supported Cable Grou<strong>ps</strong> chart following the FAStT 200 configuration examples for cable type definitions.<br />

P<br />

P<br />

P<br />

P<br />

P<br />

D1 or D2 2<br />

D1 or D2 2<br />

D1 or D2 2<br />

D1 or D2 2<br />

D1 or D2 2<br />

D1 or D2 2<br />

D1 or D2 2<br />

P<br />

P<br />

FAStT EXP500<br />

FAStT EXP500<br />

FAStT EXP500<br />

FAStT EXP500<br />

FAStT EXP500<br />

FAStT EXP500<br />

FAStT EXP500<br />

D1<br />

D1<br />

D1<br />

S<br />

S<br />

S<br />

S<br />

S<br />

S<br />

S

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!