Part<br />

Number<br />

Updated 07/01/03<br />

Description RPM Height<br />

Bays<br />

Supported 1<br />

Maximum<br />

Quantity<br />

06P5756<br />

Hot-swap Ultra160 SCSI HDDs<br />

73.4GB 10Krpm Ultra160 SCSI Hot-Swap SL HDD 10000 SL 3 ... 5 3<br />

06P5754 18.2GB 10Krpm Ultra160 SCSI Hot-Swap SL HDD 10000 SL 3 ... 5 3<br />

06P5755 36.4GB 10Krpm Ultra160 SCSI Hot-Swap SL HDD 10000 SL 3 ... 5 3<br />

06P5767 18.2GB 15Krpm Ultra160 SCSI Hot-Swap SL HDD 15000 SL 3 ... 5 3<br />

06P5768 36.4GB 15Krpm Ultra160 SCSI Hot-Swap SL HDD 15000 SL 3 ... 5 3<br />

Optical Drives<br />

Bays<br />

Supported<br />

22P7047 8x Max Slimline DVD-ROM Drive 1<br />

2<br />

External Storage Expansion Units 2<br />

Form Factor<br />

35311RU EXP300 Storage Expansion Unit3 Rack (3U)<br />

17401RU FAStT EXP700 Storage Expansion Unit4 Rack (3U)<br />

172260U FAStT600 Storage Server (US line cord, English pubs) 5<br />

Rack (3U)<br />

35601RU FAStT EXP500 Storage Expansion Unit 6<br />

Rack (3U)<br />

35421RU FAStT200 Storage Server7, 8 Rack (3U)<br />

35422RU FAStT200 HA Storage Server7 Rack (3U)<br />

19K1121 FAStT200 Redundant RAID Controller -<br />

1. Requires removing and replacing the standard optical drive.<br />

2. To configure an external SCSI storage device, select an optional SCSI controller then refer to Appendix D: Cables - Storage Units - Controllers to confirm the controller<br />

supports the desired External Storage Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific expansion unit section.<br />

For Fibre Channel storage devices, refer to the Fibre Channel Solutions Overview section.<br />

3. EXP300 includes a single 2M Ultra2 SCSI cable and dual hot-swap 500W redundant power supplies, each with its own power cord.<br />

4. FAStT EXP700 Storage Expansion Unit (P/N 17401RU) includes dual hot-swap 400w power supplies, each with its own power cord.<br />

5. FAStT600 Storage Server includes two 390w auto-ranging redundant power supplies, each with its own power cord.<br />

6. FAStT EXP500 Storage Expansion Unit (P/N 35601RU) includes dual hot-swap 350W power supplies, each with its own power cord.<br />

7. The FAStT200 includes two hot-swap, 350W auto-ranging redundant power supplies, each with its own power cord.<br />

8. Can be upgraded to FAStT200 HA Storage Server through the addition of a FAStT200 Redundant RAID Controller (P/N 19K1121).<br />