Chapter 5. MVS-<strong>STX</strong> Display Menu<br />
The default for Span is 9999. The default for<br />
Enab is Off (graph not displayed). If enabled,<br />
the graph displays in both Manual <strong>and</strong> Auto<br />
Modes. While viewing the gross weight in<br />
Manual Mode, pressing the Enter Key toggles<br />
between bar graph <strong>and</strong> numerical display,<br />
regardless of whether the graph is enabled.<br />
Follow this procedure to set Span <strong>and</strong> Enab:<br />
1. If in Auto Mode (Auto LED illuminated),<br />
press the Auto/Man Key to put the MVS in<br />
Manual Mode. The Auto LED turns off.<br />
2. Use the Arrow Keys to scroll to the<br />
desired channel.<br />
3. Press the Menu Key to display the Main<br />
Menu. The display shows:<br />
MAIN MENU<br />
Disp I/O Cal<br />
F1 F2 F3<br />
4. Press the F1 Key to access the Disp Menu.<br />
The display shows:<br />
DISPLAY MENU<br />
Avg<br />
5. Press the Menu Key twice to display the<br />
menu’s third page. The display shows:<br />
DISPLAY MENU<br />
BarS Cont Brite<br />
F1 F2 F3<br />
6. Press the F1 Key to access BarS. The<br />
display shows:<br />
BARGRAPH MENU<br />
Span<br />
Cntby Units<br />
F1 F2 F3<br />
Enab<br />
F1 F2 F3<br />
7. Press the F1 Key to set the Span. The<br />
display looks like this:<br />
SET MAXIMUM SPAN<br />
> 9999 lbs<br />
F1 F2 F3<br />
(Units are consistent with Units Menu.)<br />
8. Use the keypad or Arrow Keys to enter the<br />
desired value. Press the Enter Key.<br />
The display acknowledges the entry <strong>and</strong><br />
returns to:<br />
BARGRAPH MENU<br />
9. Press the F3 Key to access Enab. The<br />
display shows:<br />
BARGRAPH?<br />
(Asterisk indicates the current selection.)<br />
10. Press the F1 Key to enable or the F3 Key<br />
to disable the graph. The display acknowledges<br />
the selection <strong>and</strong> returns to:<br />
BARGRAPH MENU<br />
11. Press the Esc Key to scroll up the menu<br />
tree or press the Auto/Man Key to return<br />
to channel monitoring.<br />
Cont (contrast)<br />
Display contrast is adjusted in this menu. The<br />
contrast ranges from 0 (darkest) to 255<br />
(lightest). The default is 128. Use the Arrow<br />
Keys to make fine adjustments, or the F2 <strong>and</strong><br />
F3 Keys to make coarse adjustments. The<br />
contrast changes immediately as you make<br />
the adjustment. When the desired results are<br />
attained, press the Enter Key to save the<br />
new value.<br />
Cont is set in the menu tree for any channel<br />
<strong>and</strong> applies to all channels in the system.<br />
Brite<br />
On<br />
*Off<br />
F1 F2 F3<br />
Span<br />
Enab<br />
F1 F2 F3<br />
Display brightness is adjusted in this menu<br />
(menu is functional only with purchase of<br />
Backlight option). The brightness ranges from<br />
0 (darkest) to 255 (lightest). The default is<br />
128. Use the Arrow Keys to make fine<br />
adjustments, or the F2 <strong>and</strong> F3 Keys to make<br />
coarse adjustments. The brightness changes<br />
immediately as you make the adjustment.<br />
When the desired results are attained, press<br />
the Enter Key to save the new value.<br />
Brite is set in the menu tree for any channel<br />
<strong>and</strong> applies to all channels in the system.<br />
Span<br />
Enab<br />
F1 F2 F3<br />
5-5