Motor<br />
PNU ID<br />
Access<br />
RUN Value/Range Description<br />
P7.1 113 X — Motor, rated operational current I e<br />
Note<br />
� Default values vary based on actual unit ratings.<br />
0.2 x Ie –2 x Ie (A) Ie = <strong>Frequency</strong> inverter’s rated operational current<br />
(See figure on Page 86.)<br />
Factory Setting<br />
(P1.3)<br />
P7.2 107 X — Current limit 1.5 x I e<br />
0.2 x I e –2 x I e (A) Factory setting: 1.5 x I e<br />
P7.3 112 X — Motor, rated speed �<br />
300–20000 RPM<br />
(min –1 )<br />
(See figure on Page 86.)<br />
P7.4 120 X — Motor, power factor (cos ) �<br />
0.30–1.00 (See figure on Page 86.)<br />
P7.5 110 X — Motor, rated operating voltage �<br />
180–676V (See figure on Page 86.)<br />
Pay attention to the supply voltage and the type of<br />
circuit in the stator winding<br />
P7.6 111 X — Motor, rated frequency 60.00<br />
30–320 Hz (See figure on Page 86.)<br />
Parameters<br />