Digital Inputs, continued<br />
PNU ID<br />
Access<br />
RUN Value/Range Description<br />
P3.6 406 — Ext. fault open (N/C) 0<br />
Like P3.2 Allocation of the function to control signal terminals<br />
Error message when switching off or interrupting<br />
(wire-breakage-safe) the applied control voltage (+24V) from<br />
the assigned control signal terminal (DI1 to DI6)<br />
P3.7 414 — Fault reset 5<br />
Like P3.2 Allocation of the function to control signal terminals<br />
Acknowledges a displayed error message (Reset) when<br />
switching on +24V on the assigned control signal terminal<br />
(DI1 to DI6)<br />
P3.8 407 — Run enable 0<br />
Like P3.2 Allocation of the function to control signal terminals<br />
Rotational direction-independent start release when switching<br />
on +24V on the assigned control signal terminal (DI1 to DI6)<br />
P3.9 419 — Fixed frequency, binary value B0 3<br />
Like P3.2 Allocation of the function to control signal terminals<br />
The binary connection of three digital inputs enable calling<br />
seven fixed frequencies (eight fixed frequencies if parameter<br />
P6.2 = 0 is set)<br />
The limitation of the fixed frequencies is done based on<br />
parameters P6.3 (minimum frequency) and P6.4 (maximum<br />
frequency)<br />
The switch between the individual fixed frequencies is done<br />
with the acceleration time and deceleration times in P6.5<br />
and P6.6<br />
Input (Binary) Fixed <strong>Frequency</strong><br />
B0 B1 B2 (Factory setting)<br />
FF0, P10.1 = 5 Hz,<br />
only if P6.2 = 0<br />
X FF1, P10.2 = 10 Hz<br />
X FF2, P10.3 = 15 Hz<br />
X X FF3, P10.4 = 20 Hz<br />
X FF4, P10.5 = 25 Hz<br />
X X FF5, P10.6 = 30 Hz<br />
X X FF6, P10.7 = 40 Hz<br />
X X X FF7, P10.8 = 50 Hz<br />
Parameters<br />
Factory Setting<br />
(P1.3)<br />
M-Max <strong>Series</strong> <strong>Adjustable</strong> <strong>Frequency</strong> <strong>Drive</strong> MN04020003E—April 2011 www.eaton.com 71