Control Signal Terminals Arrangement and Connections<br />

ESD Measures<br />

WARNING<br />

Discharge yourself on a grounded surface before<br />

touching the control signal terminals and the controller<br />

PCB. This protects the device from destruction by<br />

electrostatic discharge.<br />

The following figure shows the arrangement and designation of M-Max control signal terminals.<br />

Control Signal Terminals Assignments and Designations<br />

Possible Connection Line Sizes and Specifications on Control Signal Terminals<br />

Microswitches and Control Signal Terminals<br />

Four microswitches are arranged under the cover plate. These are used to directly configure the<br />

control signal terminals.<br />

Microswitch Factory Settings<br />

AI2 GND DO– DI4 DI5 DI6 AO DO+ R13 R14 – R24<br />

4 5 13 14 15 16 18 20 22 23 26<br />

1 2 3 6 7 8 9 10 25 24<br />

+10V AI1 GND 24V DI-C DI1 DI2 DI3 A B R21 R22<br />

mm2 mm2 AWG mm Nm ft-lbs mm<br />

0.14–1.5 0.25–0.5 26–16 5 0.22–0.25 0.16–0.18 0.4 x 2.5<br />

AI2 GND DO– DI4 DI5 DI6 AO DO+ R13 R14 – R24<br />

4 5 13 14 15 16 18 20 22 23 26<br />

1 2 3 6 7 8 9 10 25 24<br />

+10V AI1 GND 24V DI-C DI1 DI2 DI3 A B R21 R22<br />

S1 = LOGIC (+)<br />

LOGIC<br />

– +<br />

AI 1<br />

V mA<br />

AI 2<br />

V mA<br />

RS 485<br />

– Term.<br />

S4 = RS485 (–)<br />

S3 = AI2 (mA)<br />

S2 = AI1 (V)<br />

M3<br />

Microswitch Description<br />

S1 LOGIC Control logic:<br />

+ = Positive logic (FS)<br />

Source type<br />

– = Negative logic<br />

Sink type<br />

S2 AI1 Analog input 1 (P2.1):<br />

V = 0–10V (FS)<br />

mA = 4–20 mA<br />

S3 AI2 Analog input 2 (P2.5):<br />

mA = 4–20 mA (FS)<br />

V = 0 –10V<br />

S4 RS485 Bus terminating resistor<br />

(control signal terminal A/B):<br />

– = Disconnected<br />

Term. = Switched on (terminator)<br />