M-Max <strong>Series</strong> Overview<br />
General Rated Operational Data, continued<br />
Description Symbols � Power Section<br />
Unit Specification<br />
Rated operational voltage fLN Hz at 50/60<br />
MMX11 Ue Vac 1~115 (110 –15% to 120 +10%)<br />
MMX12 Ue Vac 1~230 (208 –15% to 240 +10%)<br />
MMX32 Ue Vac 3~230 (208 –15% to 240 +10%)<br />
MMX34 Ue Vac 3~400 (380 –15% to 480 +10%)<br />
MMX35 Ue Vac 3~575 (–15% to 15%)<br />
Input network configuration<br />
— — Center-point grounded star network (TN-S network)<br />
(AC power supply network)<br />
Phase grounded AC networks are not permitted<br />
Input switch-on frequency — — Maximum one time per minute<br />
Input current THD % >120<br />
Short-circuit current IK kA Maximum 12k ohms<br />
Permitted residual ripple with external<br />
control voltage (+24V)<br />
— — Max. 5% Ua /Ua Input, analog, parameterizable,<br />
selection via microswitches<br />
— — 2 x 0 (2) to +10 Vdc, Ri >200k ohms or 0 (4) to 20 mA, RB ~200 ohms<br />
Resolution — Bit 10<br />
Output, digital, parameter definable — — 1 x transistor: 48 Vdc, max. 50 mA<br />
Output relay, parameter definable — — 1 x N/O: 250 Vac, maximum 2A or 250 Vdc, max. 0.4A<br />
Output relay, parameter definable — — 1 x changeover contact: 250 Vac, maximum 2A or 250 Vdc, maximum 0.4A<br />
Serial interface — — RS485/Modbus ® RTU<br />
Notes<br />
� Symbols used in technical data and formulas.<br />
� 122°F (50°C) with lateral clearance of 0.79 in (20 mm) and reduced pulse frequency 4 kHz and altitude 1000m.<br />
10 M-Max <strong>Series</strong> <strong>Adjustable</strong> <strong>Frequency</strong> <strong>Drive</strong> MN04020003E—April 2011 www.eaton.com