System Parameter<br />

The system parameters (S parameters) inform the user of device-specific settings.<br />

The S parameters are not visible (i.e. hidden), as long as you have activated the quick start<br />

assistant (P1.1 = 1, see “Parameter Menu (PAR)” on Page 62).<br />

System Parameter<br />

PNU ID<br />

Access<br />

RUN Value/Range Description<br />

Hard- and Software Information<br />

S1.1 833 X xx API SW ID —<br />

S1.2 834 X x API SW Version —<br />

S1.3 835 X x Power SW ID —<br />

S1.4 836 X xx Power SW Version —<br />

S1.5 837 X 90xx Application ID —<br />

S1.6 838 X x.xx Application revision —<br />

S1.7 839 X xx System load<br />

Load as percentage [%]<br />

—<br />

Communication<br />

Information on Interface RS485 (Control Signal Terminals A, B)<br />

Parameters<br />

Factory Setting<br />

(P1.3)<br />

S2.1 � 808 � X — Communication status 0.000 �<br />

xx = Number of error messages (0–64)<br />

yyy = Number of correct messages (0–999)<br />

S2.2 � 809 � — Fieldbus protocol 0 �<br />

0 Fieldbus deactivated<br />

1 Modbus RTU<br />

S2.3 � 810 � — Slave address 1 �<br />

1–255 —<br />

S2.4 � 811 � — Baud rate 5 �<br />

Transfer rate (1 Baud = 1 symbol per second)<br />

The baud rate must be equal on the send and receive sides<br />

0 = 300 Baud<br />

1 = 600 Baud<br />

2 = 1200 Baud (1.2k Baud)<br />

3 = 2400 Baud (2.4k Baud)<br />

4 = 4800 Baud (4.8k Baud)<br />

5 = 9600 Baud (9.6k Baud)<br />

6 = 19200 Baud (19.2k Baud)<br />

7 = 38400 Baud (38.4k Baud)<br />

8 = 57600 Baud (57.6k Baud)<br />

Note<br />

� With a fieldbus connection (option, for example, CANopen, PROFIBUS DP, and so on) modified ID numbers and different factory settings are stored here.<br />

Detailed information is provided in the specific manuals of the relevant fieldbus interface card.<br />