Parameters<br />

Digital Outputs, continued<br />

PNU ID<br />

Access<br />

RUN Value/Range Description<br />

P5.5 316 — <strong>Frequency</strong> monitoring 1 reference value 0.00<br />

0.00–P6.4 Hz —<br />

P5.6 346 — <strong>Frequency</strong> monitoring 2<br />

Monitoring of the selected frequency range<br />

A monitoring message can be implemented via the digital<br />

outputs (value 11 = P5.1, P5.2, P5.3)<br />

0<br />

0 Deactivated<br />

1 0.00–P5.7 Hz<br />

2 P5.7–P6.4 Hz<br />

P5.7 347 — <strong>Frequency</strong> monitoring 2 reference value 0.00<br />

0.00–P6.4 Hz —<br />

<strong>Frequency</strong> Monitoring (P5.5–P5.7)<br />

f<br />

(Hz)<br />

P5.7<br />

P5.5<br />

P5.4 = 1–<br />

P5.4 = 2<br />

P5.6 = 1–<br />

P5.6 = 2<br />

78 M-Max <strong>Series</strong> <strong>Adjustable</strong> <strong>Frequency</strong> <strong>Drive</strong> MN04020003E—April 2011 www.eaton.com<br />

t<br />

Factory Setting<br />

(P1.3)