CAUTION<br />
Debounced inputs may not be used in the safety circuit<br />
diagram.<br />
Any contactors and switching devices on the power side are<br />
not to be opened during motor operation. Inching operation<br />
using the power switch is not permitted.<br />
Contactors and switching devices (repair and maintenance<br />
switches) on the motor side must never be opened while the<br />
motor is in operation when the frequency inverter is set to<br />
speed control operating mode (P11.8 = 1).<br />
Inching operation of the motor with contactors and switching<br />
devices in the output of the frequency inverter is not<br />
permitted.<br />
CAUTION<br />
Debounced inputs may not be used in the safety circuit<br />
diagram.<br />
Make sure that there is no danger in starting the motor.<br />
Disconnect the driven machine if there is a danger in an<br />
incorrect operational status.<br />
WARNING<br />
If a start signal is present, the drive is restarted<br />
automatically, if P3.1 = 0 is set (REAF = Restart after<br />
FAULT) and the error message has been acknowledged<br />
(Reset).<br />
WARNING<br />
If a start command is present at a digital input (DI1–DI6)<br />
assigned at P3.21, the sequence control also starts<br />
automatically (without switch edge) when the power<br />
supply is switched on (for example, after a power supply<br />
failure).<br />
CAUTION<br />
A high torque at low speed causes a high thermal load on the<br />
motor. If temperatures are too high, the motor should be<br />
equipped with an external fan.<br />
M-Max <strong>Series</strong> <strong>Adjustable</strong> <strong>Frequency</strong> <strong>Drive</strong><br />
CAUTION<br />
A high torque at low speed leads to a high thermal load on<br />
the motor.<br />
CAUTION<br />
Debounced inputs may not be used in the safety circuit<br />
diagram. DC braking results in additional heating of the<br />
motor. Configure the brake torque, set via braking current<br />
(P12.1) and the braking duration (P12.2 and P12.4), as low as<br />
possible.<br />
CAUTION<br />
Debounced inputs may not be used in the safety circuit<br />
diagram.<br />
The motor parameters must be identical in both parameter<br />
groups (P7 and P14).<br />
CAUTION<br />
Although the registers to be written are consecutive, the ID<br />
numbers of the parameter list are not. Only the ID numbers<br />
in the process data list are consecutive.<br />
CAUTION<br />
Debounced inputs may not be used in the safety circuit<br />
diagram.<br />
The inching range is not permitted via the input contactor<br />
(Pause time 60s between switching off and on).<br />
CAUTION<br />
The surface temperature of the resistors can reach values of<br />
over 212°F (100°C).<br />
M-Max <strong>Series</strong> <strong>Adjustable</strong> <strong>Frequency</strong> <strong>Drive</strong> MN04020003E—April 2011 www.eaton.com xiii