V/Hz-Characteristic Curve<br />

Access<br />

FS<br />

PNU ID RUN ro/rw Designation Value Range Page (P1.3)<br />

P11.1 108 X rw V/Hz characteristic curve 0 = Linear<br />

1 = Squared<br />

2 = Configurable<br />

105 0<br />

P11.2 602 X rw Cut-off frequency 30.00–320.00 Hz 106 60.00<br />

P11.3 603 X rw Output voltage 10.00–200.00% of the motor<br />

rated voltage (P6.5)<br />

106 100.00<br />

P11.4 604 X rw V/Hz characteristic curve,<br />

mean frequency value<br />

0.00–P11.2 Hz 107 60.00<br />

P11.5 605 X rw V/Hz characteristic curve,<br />

mean voltage value<br />

0.00–P11.3% 107 100.00<br />

P11.6 606 X rw Output voltage at 0 Hz 0.00–40.00% 107 0.00<br />

P11.7 109 X rw Torque increase 0 = Deactivated<br />

1 = Enabled<br />

107 0<br />

P11.8 600 X rw Control mode 0 = <strong>Frequency</strong> control (V/Hz)<br />

1 = Speed control with slip<br />

compensation<br />

107 0<br />

P11.9 601 X rw Carrier frequency 1.5–16.0 kHz 109 6.0<br />

P11.10 522 X rw Sine-wave filter<br />

(constant carrier frequency)<br />

0 = Deactivated<br />

1 = Enabled<br />

109 0<br />

Appendix A<br />