The following examples show two practical applications for<br />
the second parameter set.<br />
Example 1<br />
Roller conveyor with rotary table:<br />
● Motor M1 (0.75 kW) drives the rollers on the rotary table<br />
and transports the goods further<br />
● Motor M2 (1.5 kW) rotates the table for the alternating<br />
acceptance of goods from two feed lines<br />
Roller Conveyor with Rotary Table<br />
For alternating operation (rotary movement “exclusive or” of<br />
the transport rollers) on the rotary table, a frequency inverter<br />
for the largest connected load (MMX34AA4D3_) was<br />
selected.<br />
The different rating data of the motors were set in the<br />
parameter groups P7 (for motor M1) and P14 (for motor M2).<br />
The second parameter set (P14) is activated here as an<br />
example via digital input DI6 (P3.27 = 6).<br />
The change between the two motors is implemented in this<br />
example via contactors Q11 (M1) and Q12 (M2) at standstill.<br />
The enabling and selection of the relevant parameter group is<br />
activated via the digital inputs:<br />
M<br />
3<br />
● Motor M1 = DI1 (FWD, control signal terminal 8) operation<br />
with parameter group P7<br />
● Motor M2 = DI1 (FWD, control signal terminal 8) and DI6<br />
(2PS, control signal terminal 16) operation with parameter<br />
group P14 (second parameter set)<br />
˜<br />
M<br />
3<br />
˜<br />
M1<br />
M2<br />
F1<br />
Q11<br />
M1<br />
Q12<br />
F2<br />
U1 V1 W1 U1 V1 W1<br />
M<br />
3<br />
˜<br />
24V<br />
M2<br />
Parameters<br />
During maintenance and setting work the following applies<br />
for reversing duty:<br />
● Motor M1 = DI2 (REV, control signal terminal 9) operation<br />
with parameter group P7<br />
● Motor M2 = DI2 (REV, control signal terminal 9) and DI6<br />
(2PS, control signal terminal 16) operation with parameter<br />
group P14 (second parameter set)<br />
Digital input DI6 is assigned in the factory setting (P3.12 = 6)<br />
with the function PI-OFF (PID controller, deactivated). Setting<br />
P3.12 = 0 is used to switch off this function of DI6. Setting<br />
P3.27 = 6 enables the second parameter set (2PS) function<br />
to be assigned to digital input DI6.<br />
M-Max <strong>Series</strong> <strong>Adjustable</strong> <strong>Frequency</strong> <strong>Drive</strong> MN04020003E—April 2011 www.eaton.com 121<br />
M<br />
0.75 kW 1.5 kW<br />
6<br />
+24V Out<br />