Logic Function<br />
Access<br />
FS<br />
PNU ID RUN ro/rw Designation Value Range Page (P1.3)<br />
P13.1 1453 X rw LOG function,<br />
0 = Deactivated<br />
117 0<br />
selection input A<br />
1 = READY<br />
2 = RUN<br />
3 = FAULT<br />
4 = Error message (inverted)<br />
5 = ALARM<br />
6 = REV<br />
7 = Output frequency = frequency setpoint<br />
8 = Motor controller active<br />
9 = Zero frequency<br />
10 = <strong>Frequency</strong> monitoring 1<br />
11 = <strong>Frequency</strong> monitoring 2<br />
12 = PID monitoring<br />
13 = Overtemperature signal<br />
14 = Overcurrent control active<br />
15 = Overvoltage control active<br />
16 = PLC sequence control active<br />
17 = PLC sequence control, single step<br />
completed<br />
18 = PLC sequence control, program cycle<br />
completed<br />
19 = PLC Sequence control, pause<br />
20 = Counter, value 1 reached<br />
21 = Counter, value 2 reached<br />
22 = RUN message active<br />
23 = Analog min. reference error<br />
24 = LOG function fulfilled<br />
25 = PID controller, actual value<br />
monitoring<br />
26 = External brake actuated<br />
27 = Current monitoring<br />
28 = Fieldbus, remote output<br />
P13.2 1454 X rw LOG function, selection<br />
input B<br />
P13.3 1455 X rw LOG function, select<br />
operation<br />
Like P13.1 118 0<br />
0 = A AND B<br />
1 = A OR B<br />
2 = A XOR B<br />
118 0<br />
Appendix A<br />
User<br />
Setting<br />
M-Max <strong>Series</strong> <strong>Adjustable</strong> <strong>Frequency</strong> <strong>Drive</strong> MN04020003E—April 2011 www.eaton.com 161