E. Motor sizes have been selected for non-overloading conditions. Motor brake horsepower shall notbe exceeded at any point of the pump characteristic curve and shall not exceed 100 percent ofnominal motor horsepower under any condition of pump load. Motor efficiency shall be asspecified in 15050.2 .2 IN-LINE CIRCULATING PUMP (HWP-1 & HWP-2)A. In-line centrifugal, single stage, wet rotor, close coupled pump, rated for continuous operationfrom 60°F to 230°F for heating water service. Capacity as shown. Series 200, by Grundfos,Clovis, CA, or approved equal.B. Casing: Cast iron with unions or threaded companion flanges for piping connections and threadedgage tappings at inlet and outlet connections.C. Impeller: Stainless steel; statically and dynamically balanced, and secured to stainless steel motorshaft.D. Shaft Seal and Coupling: Not Used.E. Bearings: Carbon thrust bearing, chrome carbide journals, ceramic radial bearings.F. Motor: Three-speed, voltage, phase and frequency as shown, cooled and lubricated by pumpedfluid.2 .3 IN-LINE CIRCULATING PUMP (CHP-1 & CHP-2)A. In-line, centrifugal, single-stage, split case, close coupled pump, rated for continuous operation for40°F chilled water service. Capacity as shown. Series 7000 by Grundfos, Clovis, CA, orapproved equal.B. Casing: Cast iron with unions or threaded companion flanges for piping connections and threadedgage tappings at inlet and outlet connections.C. Impeller: Stainless steel; statically and dynamically balanced, and secured to stainless steel shaft.D. Seals: Mechanical type, stainless steel with tungsten carbide rotating face.E. Coupling: Cast iron, for direct coupling of pump and motor.F. Motor: Open dripproof, minimum 1.15 service factor, voltage, phase and frequency as shown.2 .4 VIBRATION ISOLATIONA. As specified in Section 15070.PART 3 EX<strong>EC</strong>UTION3 .1 <strong>GENERAL</strong>A. Discharge increasers shall be concentric and located at pump discharge nozzle. Suction pipingreducers shall be eccentric and located at pump suction nozzle. Horizontal elbows shall not beused at pump suction. Provide purge cock and drain cock in circulator casing, and gauge tappingsin pump nozzles.SEKI-507 15130-2PUMPS

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!