<strong>Control</strong> Technology, Microelectronics and Nanotechnologyoffset. This is <strong>the</strong> amount by which <strong>the</strong> process is off setpo<strong>in</strong>t.The ga<strong>in</strong> of <strong>the</strong> controller can be <strong>in</strong>creased which narrows <strong>the</strong>throttl<strong>in</strong>g range of <strong>the</strong> system and makes <strong>the</strong> operat<strong>in</strong>g l<strong>in</strong>e more horizontal.Increas<strong>in</strong>g <strong>the</strong> ga<strong>in</strong>, can reduce, but not do away with <strong>the</strong> offset.At high ga<strong>in</strong>s <strong>the</strong> presence of <strong>the</strong> offset is no longer appreciable and itseems as if <strong>the</strong> controller is keep<strong>in</strong>g <strong>the</strong> process on setpo<strong>in</strong>t.Most control loops become unstable if <strong>the</strong> controller is providedwith a high ga<strong>in</strong>. The exceptions are very slow processes. This limits <strong>the</strong>use of pla<strong>in</strong> proportional control to processes which can tolerate highcontroller ga<strong>in</strong>s, <strong>the</strong> narrow proportional bands found <strong>in</strong> <strong>the</strong>rmostatsand humidostats. The addition of an <strong>in</strong>ternal feedback mechanism effectivelyreduces <strong>the</strong> sensitivity of <strong>the</strong> device to an acceptable range forproportional control.Integral ModeThis mode is also known as reset mode, s<strong>in</strong>ce after a load change itreturns <strong>the</strong> controlled variable to setpo<strong>in</strong>t and resets or elim<strong>in</strong>ates <strong>the</strong> offsetwhich <strong>the</strong> proportional controller would cause. This mode is alsoknown as float<strong>in</strong>g control. But, it is most often called <strong>in</strong>tegral control s<strong>in</strong>ce<strong>the</strong> controller output is based on <strong>the</strong> <strong>in</strong>tegral of <strong>the</strong> controller <strong>in</strong>put.Proportional-plus Integral <strong>Control</strong>In a proportional-plus <strong>in</strong>tegral controller <strong>the</strong> controller output is acomb<strong>in</strong>ation of <strong>the</strong> <strong>in</strong>tegral and proportional value (Figure 3-3). The<strong>in</strong>tegral term is divided by <strong>the</strong> <strong>in</strong>tegral time sett<strong>in</strong>g of <strong>the</strong> controller,which is also called <strong>the</strong> reset time.Figure 3-3. Proportional-plus-<strong>in</strong>tegral control.©2001 by The Fairmont Press, Inc. All rights reserved.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!