12.07.2015 Views

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>HVAC</strong> <strong>Control</strong> <strong>in</strong> <strong>the</strong> <strong>New</strong> <strong>Millennium</strong>electric cooler while a cont<strong>in</strong>uous sample of <strong>the</strong> atmosphere passes over<strong>the</strong> mirror. The mirror is illum<strong>in</strong>ated by a light source and observed bya photodetector bridge network.As condensate forms on <strong>the</strong> mirror, <strong>the</strong> change <strong>in</strong> reflectance isdetected by a reduction <strong>in</strong> <strong>the</strong> reflected light level received by <strong>the</strong> photodetectorbecause of <strong>the</strong> light-scatter<strong>in</strong>g effect of <strong>the</strong> <strong>in</strong>dividual dewmolecules. This light reduction forces <strong>the</strong> optical bridge toward a balancepo<strong>in</strong>t, reduces <strong>the</strong> <strong>in</strong>put error signal to <strong>the</strong> amplifier, and proportionallycontrols <strong>the</strong> drive from <strong>the</strong> power supply to <strong>the</strong> <strong>the</strong>rmoelectriccooler (Figure 4-3). This ma<strong>in</strong>ta<strong>in</strong>s <strong>the</strong> mirror at a temperature at whicha constant-thickness dew layer is reta<strong>in</strong>ed. Embedded <strong>in</strong> <strong>the</strong> mirror, atemperature-measur<strong>in</strong>g element measures <strong>the</strong> dew po<strong>in</strong>t temperature.Advances <strong>in</strong> <strong>the</strong> technology of <strong>the</strong>rmoelectric coolers allow practical<strong>in</strong>struments with several stages of <strong>the</strong>rmoelectric cool<strong>in</strong>g for most dewpo<strong>in</strong>t ranges.Relative humidity is controlled at <strong>the</strong> zone level. The control actionis based on <strong>the</strong> relative humidity read<strong>in</strong>g <strong>in</strong> <strong>the</strong> comb<strong>in</strong>ed return airstream from <strong>the</strong> workstations <strong>in</strong> that zone.Figure 4-3. Chilled mirror hygrometer.©2001 by The Fairmont Press, Inc. All rights reserved.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!