12.07.2015 Views

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Computer Networks and SecurityGateway AccessMasters that behave as a slave <strong>in</strong> a field-bus network act as couplersor gateways. These AS-i gateways provide access to sensor andactuator data from all layers of <strong>the</strong> automation architecture. AS-i gatewaysare available for Profibus, Interbus, DeviceNet, CAN, SDS,MODBUS, MODBUS+ and RS-232/-422/-485. Stand-alone masters actas controllers for simple tasks.An As-i power supply unit serves as <strong>the</strong> power supply for <strong>the</strong>slaves. It forms <strong>the</strong> voltage pulses for data transmission and can beconnected to <strong>the</strong> network at any po<strong>in</strong>t. It feeds a symmetrical supplyvoltage of 30 VDC <strong>in</strong>to <strong>the</strong> cable. Power supplies are available withrat<strong>in</strong>gs of 2.2 to 8-A.AS-i CableThe standard AS-i cable is 2-core, 2 by 1.5-mm, rubber <strong>in</strong>sulated,with a special profile that prevents reversal of <strong>the</strong> poles when connect<strong>in</strong>gdevices. The electrical connection is made by penetration contacts,which pierce <strong>the</strong> rubber <strong>in</strong>sulation to make a connection to <strong>the</strong> two cablewires. This connection method elim<strong>in</strong>ates stripp<strong>in</strong>g and term<strong>in</strong>at<strong>in</strong>g.If a device needs to be moved to ano<strong>the</strong>r location on <strong>the</strong> cable, itis easily done. The cable is self-heal<strong>in</strong>g and holes made <strong>in</strong> <strong>the</strong> cabledur<strong>in</strong>g <strong>in</strong>stallation close when <strong>the</strong> connection is removed.Cables are available for applications that require data and powerseparately. A black cable is used for supply voltages up to 30-V and a redversion for supply voltages up to 230-VAC. Table 8-1 lists <strong>the</strong> AS-i cablecharacteristics.Table 8-1. AS-i Cable Characteristics————————————————————————————————Trapezoidal mechanically coded cableReverse voltage protectionOil-resistant versionsUL recommendedData and power, yellow version - 30 VDCPower - 24 VDC (black) to 230 (red) VACPierc<strong>in</strong>g connectors————————————————————————————————©2001 by The Fairmont Press, Inc. All rights reserved.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!