12.07.2015 Views

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Energy and Power Management, Distributed <strong>Control</strong> Trendspriate zone level controllers to provide build<strong>in</strong>g-wide functions.Equipment level applications are energy <strong>in</strong>tensive and <strong>in</strong>clude airhandlers, chillers and boilers. The characteristics of <strong>the</strong> control <strong>in</strong>cludedata po<strong>in</strong>t monitor<strong>in</strong>g and multiple control sequences such as reset andwarm-up.<strong>Control</strong> LoopsBuild<strong>in</strong>g-wide control systems depend on control loops to regulate<strong>the</strong> different parts of <strong>the</strong> control hardware. These can be categorized <strong>in</strong>totwo types, closed and open loops.An open loop uses a controller that starts and stops <strong>the</strong> <strong>HVAC</strong>equipment at given times. There is no feedback to <strong>the</strong> controller abouttemperature or o<strong>the</strong>r controlled variables.In a closed loop <strong>the</strong> controller responds to cont<strong>in</strong>uous environmentaldata and compares <strong>the</strong>m to a programmed environmental setpo<strong>in</strong>t(temperature, humidity, air quality).In a closed-loop system, <strong>the</strong> sens<strong>in</strong>g element provides feedback<strong>in</strong>formation to <strong>the</strong> controller. These data are compared by <strong>the</strong> controllerto <strong>the</strong> setpo<strong>in</strong>t that has been adjusted by <strong>the</strong> user.The controller sends a corrective signal to <strong>the</strong> controlled hardware.The sens<strong>in</strong>g element cont<strong>in</strong>uously monitors <strong>the</strong> environment and outputsnew data to <strong>the</strong> controller. The controller monitors <strong>the</strong> sensors andactivates or controls <strong>the</strong> devices to compensate for any needed environmentaladjustments.Digital LogicThe logic circuits <strong>in</strong> digital computers th<strong>in</strong>k and respond <strong>in</strong> termsof on and off logic. This may be a yes or no, one or zero, open or closedor true or false logic state. This b<strong>in</strong>ary logic is converted <strong>in</strong>to electricalsignals which are def<strong>in</strong>ed as a true or false digital signal.The digital signal <strong>in</strong> a <strong>HVAC</strong> relay is represented by a set of openor closed contacts. The controller may <strong>in</strong>terpret an <strong>in</strong>put device signal asa request or non-request for heat<strong>in</strong>g.A digital signal on <strong>the</strong> output of a microprocessor usually activatesa contactor (relay) to ei<strong>the</strong>r open or close. The system can use this open©2001 by The Fairmont Press, Inc. All rights reserved.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!