12.07.2015 Views

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>HVAC</strong> <strong>Control</strong> <strong>in</strong> <strong>the</strong> <strong>New</strong> <strong>Millennium</strong>particular sensor. Most RTD temperature sensors can be obta<strong>in</strong>ed withconstants that are <strong>the</strong>n programmed <strong>in</strong>to a transmitter that uses <strong>the</strong>equation to correct for divergence.Us<strong>in</strong>g a 1000 ohm RTD ra<strong>the</strong>r than a 100 ohm unit will give bettermeasurement resolution, s<strong>in</strong>ce each degree change <strong>in</strong> temperature willresult <strong>in</strong> a resistance change ten times greater.Us<strong>in</strong>g <strong>the</strong> digital output from a smart transmitter <strong>in</strong>stead of ananalog output will provide higher accuracy. This elim<strong>in</strong>ates <strong>the</strong> errorassociated with <strong>the</strong> D/A converter.StabilityAccuracy is <strong>the</strong> level of uncerta<strong>in</strong>ty of a transmitter’s or sensor’soutput at a given time while stability is <strong>the</strong> uncerta<strong>in</strong>ty of a transmitter’sor sensor’s output over a period of time. Stability is usually specified asa percent of temperature span per year. It <strong>in</strong>dicates how often <strong>the</strong> systemwill need calibration.Total accuracy also depends on <strong>the</strong> equipment used to calibrate <strong>the</strong>measurement loop. Test equipment should provide a 3:1 accuracy ratio,where <strong>the</strong> test device is rated at least three times more accurate than <strong>the</strong>unit under calibration. Equipment should be traceable to an accreditedmetrology <strong>in</strong>stitute such as NIST (National Institute of Standards andTechnology).Humidity <strong>Control</strong>The relative humidity sensors are <strong>in</strong>stalled <strong>in</strong> <strong>the</strong> return air stream.The relative humidity <strong>in</strong> <strong>the</strong> clean room should be with<strong>in</strong> RH +3% so <strong>the</strong>humidity sensor must have an error of less than ±3% RH. The repeatabilityof human hair element sensors is about ±1% RH. These units can beused for clean rooms provided that <strong>the</strong>y are <strong>in</strong>dividually calibrated foroperation at or around 35% RH. Without <strong>in</strong>dividual calibration, <strong>the</strong>ywill not perform satisfactorily <strong>in</strong> this application, s<strong>in</strong>ce <strong>the</strong>ir off-<strong>the</strong>-shelferror, is about +5% RH.Hair HygrometersThese devices operate by a change of length of organic and syn<strong>the</strong>ticfibers when <strong>the</strong>se are exposed to a moist atmosphere. A mechani-©2001 by The Fairmont Press, Inc. All rights reserved.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!