12.07.2015 Views

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>HVAC</strong> <strong>Control</strong> <strong>in</strong> <strong>the</strong> <strong>New</strong> <strong>Millennium</strong>decision-mak<strong>in</strong>g circuits are comb<strong>in</strong>ed with a customized program tomaximize demand and energy sav<strong>in</strong>gs with a m<strong>in</strong>imum impact on operat<strong>in</strong>gconditions. The computer receives <strong>in</strong>puts from <strong>the</strong> electric meterand from sensors monitor<strong>in</strong>g <strong>the</strong> critical loads <strong>in</strong> <strong>the</strong> build<strong>in</strong>g or facility.Loads may be cycled based on <strong>the</strong> follow<strong>in</strong>g criteria:• maximum demand target,• time of day and day or week,• rate of demand <strong>in</strong>crease,• heat<strong>in</strong>g and cool<strong>in</strong>g temperatures,• pressures,• fuel flow and rates,• occupancy schedules,• <strong>in</strong>side and outside temperatures,• humidity,• w<strong>in</strong>d direction and velocity and• comb<strong>in</strong>ations of <strong>the</strong> above factors.The durations are variable and can be changed automatically accord<strong>in</strong>gto <strong>the</strong>se parameters. A secondary demand target may be usedand if <strong>the</strong> primary demand target is exceeded o<strong>the</strong>r control actions areapplied.The demand target can float upward and downward accord<strong>in</strong>g todemand rates, time of day, and o<strong>the</strong>r parameters. Different targets andcontrol strategies can be applied to different sections of build<strong>in</strong>gs andplants. Reports and graphs show<strong>in</strong>g <strong>the</strong> consumption by demand periodand by day, week, or month are provided.These systems can also be applied to manage <strong>the</strong> energy consumedby air condition<strong>in</strong>g systems. Intake and exhaust dampers are controlledon <strong>the</strong> basis of air temperatures, so that <strong>the</strong> mix of air requir<strong>in</strong>g <strong>the</strong> leastenergy is obta<strong>in</strong>ed at all times. The start-up and shutdown of air condition<strong>in</strong>g,heat<strong>in</strong>g, and light<strong>in</strong>g systems can be regulated accord<strong>in</strong>g to<strong>in</strong>side and outside temperatures as well as occupancy. The goal is toproduce <strong>the</strong> conditions which consume <strong>the</strong> least energy.©2001 by The Fairmont Press, Inc. All rights reserved.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!