12.07.2015 Views

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>HVAC</strong> <strong>Control</strong> <strong>in</strong> <strong>the</strong> <strong>New</strong> <strong>Millennium</strong>approximately 0.50 and substitution of values <strong>in</strong> <strong>the</strong> above equationgives:H = 0.50 × 100(70 - 10) = 3000 Btu/hourNatural VentilationThe natural forces that move air through and out of build<strong>in</strong>gs <strong>in</strong>cludew<strong>in</strong>d forces and temperature differences between <strong>the</strong> <strong>in</strong>side and<strong>the</strong> outside. Air movement can be caused by ei<strong>the</strong>r of <strong>the</strong>se forces act<strong>in</strong>galone or <strong>in</strong> comb<strong>in</strong>ation, depend<strong>in</strong>g on atmospheric conditions, build<strong>in</strong>gdesign, and location.The use of natural forces for produc<strong>in</strong>g ventilation can <strong>in</strong>volve <strong>the</strong>follow<strong>in</strong>g conditions:• average w<strong>in</strong>d velocity,• prevail<strong>in</strong>g w<strong>in</strong>d direction,• seasonal and daily variations <strong>in</strong> w<strong>in</strong>d velocity and direction, and• local w<strong>in</strong>d <strong>in</strong>terference by build<strong>in</strong>gs and o<strong>the</strong>r obstructions.Without obstructions to change <strong>the</strong> w<strong>in</strong>d’s direction, <strong>the</strong> movements of<strong>the</strong> airstream along with <strong>the</strong> pressure, rema<strong>in</strong> constant.Air leakage occurs through <strong>the</strong> build<strong>in</strong>g’s cracks or open<strong>in</strong>gs. Thecold and heavy air enters at low levels and pushes <strong>the</strong> warm and lightair out at higher levels. The same draft takes place <strong>in</strong> a chimney.Temperature-difference ForcesThe draft <strong>in</strong> a stack or chimney is known as <strong>the</strong> flue effect. The flueeffect of a stack is produced <strong>in</strong> a build<strong>in</strong>g when <strong>the</strong> outdoor temperatureis lower than <strong>the</strong> stack temperature. It is due to <strong>the</strong> difference <strong>in</strong> weightof <strong>the</strong> warm column of air <strong>in</strong> <strong>the</strong> stack and <strong>the</strong> cooler air outside. Theflow due to <strong>the</strong> flue effect is proportional to <strong>the</strong> square root of <strong>the</strong> draf<strong>the</strong>ad, and is given by <strong>the</strong> follow<strong>in</strong>g approximate relation:Q=9.4Ah t ± t o©2001 by The Fairmont Press, Inc. All rights reserved.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!