12.07.2015 Views

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

HVAC Control in the New Millennium.pdf - HVAC.Amickracing

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Computer Networks and Securityand fewer options.BACnet provides an alternative s<strong>in</strong>ce <strong>the</strong>re are a set of rules thatallow <strong>the</strong> major components of a system, even if <strong>the</strong>y are manufacturedby different vendors, to function toge<strong>the</strong>r. They can <strong>in</strong>teroperate. This<strong>in</strong>teroperability promises to provide competitive pric<strong>in</strong>g, more choicesfor products and service, and <strong>the</strong> ability to even operate two differentsystems with a s<strong>in</strong>gle computer station.BACnet is well documented and robust <strong>in</strong> design. It has <strong>the</strong> featuresneeded and has headroom for <strong>the</strong> future. Manufacturers that seeBACnet as an opportunity will adopt it.The complete BACnet standard covers about seven different datal<strong>in</strong>k layer models. But, a BACnet compliant product on an ARCNET leveland a BACnet compliant product on a sensor level does not establish<strong>in</strong>teroperability. If BACnet is not used <strong>in</strong>ternally <strong>in</strong> some new products,<strong>the</strong>n a gateway will be required and that gateway can act as a firewall.A firewall might be used by an equipment manufacturer of chillersand boilers, to protect <strong>the</strong> equipment’s <strong>in</strong>ternal safety logic and criticalcontrol algorithms. If this logic is compromised, it can create a warrantyor liability issue.At m<strong>in</strong>imal compliance, it does not make much difference whatk<strong>in</strong>d of system or what communications protocols are used <strong>in</strong> collect<strong>in</strong>gdata or <strong>in</strong> issu<strong>in</strong>g field commands. What is important, is what data arega<strong>the</strong>red from any given piece of equipment, and how that data arestructured. Us<strong>in</strong>g this strategy and basic network tools, <strong>in</strong>formationga<strong>the</strong>red from multiple field systems can be presented as a s<strong>in</strong>gle system,to multiple users.One problem with a BACnet m<strong>in</strong>imum level of compliance, is thatit is not easy to make programm<strong>in</strong>g changes. In most cases, programm<strong>in</strong>gmust be done at <strong>the</strong> controller connected to <strong>the</strong> field equipment.Full compliance allows programm<strong>in</strong>g as well as monitor<strong>in</strong>g andcontrol functions at <strong>the</strong> user level. Most manufacturers have offeredBACnet compatibility at <strong>the</strong> m<strong>in</strong>imum compliance level.Conformance ClassificationsThe BACnet standard def<strong>in</strong>es conformance classes which aregroups of functions and capabilities needed to allow specific levels <strong>in</strong>BACnet communications. The protocol’s hierarchy of conformance©2001 by The Fairmont Press, Inc. All rights reserved.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!