Advanced <strong>HVAC</strong> <strong>Control</strong>, Information Technology and Open Systemsdeterm<strong>in</strong>es <strong>the</strong> saturation partial pressure of <strong>the</strong> water vapor. This relationshipis used by <strong>the</strong> National Bureau of Standards for humidity sensorcalibration. The saturation vapor pressures over plane surfaces ofpure water and pure ice correspond to equivalent dew po<strong>in</strong>ts or frostpo<strong>in</strong>ts.The equilibrium partial pressure is illustrated <strong>in</strong> Figure 4-2. At <strong>the</strong>saturation temperature, or dew po<strong>in</strong>t, <strong>the</strong> gas mixture is saturated withrespect to water or ice and <strong>the</strong> rate of water molecules leav<strong>in</strong>g <strong>the</strong> atmosphereand condens<strong>in</strong>g on <strong>the</strong> chilled surface is <strong>the</strong> same as <strong>the</strong> rate ofwater molecules leav<strong>in</strong>g <strong>the</strong> chilled surface and reenter<strong>in</strong>g <strong>the</strong> atmosphere.At equilibrium saturation, <strong>the</strong> water vapor partial pressure of<strong>the</strong> condensate is equal to <strong>the</strong> water vapor partial pressure of <strong>the</strong> gasatmosphere.This equilibrium at <strong>the</strong> mirror surface is obta<strong>in</strong>ed by cool<strong>in</strong>g <strong>the</strong>mirror to <strong>the</strong> saturation temperature. A temperature sensor is <strong>in</strong> direct<strong>the</strong>rmal contact with <strong>the</strong> mirror, and <strong>the</strong> mirror temperature is used<strong>in</strong>directly as <strong>the</strong> dew po<strong>in</strong>t or saturation temperature.The cool<strong>in</strong>g of <strong>the</strong> mirror surface may be accomplished with mechanicalrefrigeration. More recent units use <strong>the</strong>rmoelectric heat pumps.Detection of <strong>the</strong> condensation is done with optical phototransistor detection.The newer units automatically control <strong>the</strong> surface at <strong>the</strong> dew po<strong>in</strong>tor frost po<strong>in</strong>t.Manually cooled, visually observed hygrometers are known asdew cups. These devices have been replaced by <strong>the</strong> <strong>the</strong>rmoelectricallycooled, optically observed dew po<strong>in</strong>t hygrometer for on-l<strong>in</strong>e measurement.Here, <strong>the</strong> mirror surface is chilled to <strong>the</strong> dew po<strong>in</strong>t by a <strong>the</strong>rmo-Figure 4-2. Equilibrium partial pressure.©2001 by The Fairmont Press, Inc. All rights reserved.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!