Q. Section 1505.1.3 <strong>of</strong> the California Building <strong>Code</strong> is deleted in its entirety and readopted to read as follows:<br />

1505.1.3 Ro<strong>of</strong> Coverings in all Other Areas. The ro<strong>of</strong> covering or ro<strong>of</strong>ing assembly <strong>of</strong> any new building<br />

or the re-ro<strong>of</strong>ing <strong>of</strong> any existing building, regardless <strong>of</strong> type or occupancy classification, shall be no less than Class B,<br />

except that Group H, Division 1 and Group I occupancies shall be Class A. Treated or untreated wood shakes or<br />

shingles shall not be permitted, except on existing structures which are constructed with shake or shingle ro<strong>of</strong>s where<br />

less than 20 % <strong>of</strong> the existing ro<strong>of</strong> is being replaced within a two 2 year period, provided such replacement ro<strong>of</strong>ing is<br />

fire retardant treated wood shakes or shingles.<br />

Exception: In the High Fire Hazard District, ro<strong>of</strong> coverings shall be in accordance with Chapter 7A as<br />

amended.<br />

R. Section 1704.1 <strong>of</strong> the California Building <strong>Code</strong> is amended to read as follows:<br />

1704.1 General. Where application is made for construction as described in this section, the owner or the<br />

registered design pr<strong>of</strong>essional in responsible charge acting as the owner’s agent shall employ one or more special<br />

inspectors to provide inspections during construction on the types <strong>of</strong> work listed under Section 1704. These<br />

inspections are in addition to the inspections specified in Section 110.<br />

The special inspector shall be a qualified person who shall demonstrate competence, to the satisfaction <strong>of</strong> the<br />

building <strong>of</strong>ficial, for inspection <strong>of</strong> the particular type <strong>of</strong> construction or operation requiring special inspection. The<br />

registered design pr<strong>of</strong>essional in responsible charge and engineers <strong>of</strong> record involved in the design <strong>of</strong> the project are<br />

permitted to act as the approved agency and their personnel are permitted to act as the special inspector for the work<br />

designed by them, provided those personnel meet the qualification requirements <strong>of</strong> this section to the satisfaction <strong>of</strong><br />

the building <strong>of</strong>ficial. The special inspector shall provide written documentation to the building <strong>of</strong>ficial demonstrating<br />

his or her competence and relevant experience or training. Experience or training shall be considered relevant when<br />

the documented experience or training is related in complexity to the same type <strong>of</strong> special inspection activities for<br />

projects <strong>of</strong> similar complexity and material qualities. These qualifications are in addition to qualifications specified in<br />

other sections <strong>of</strong> this code.<br />

Exceptions:<br />

1. Special inspections are not required for work <strong>of</strong> a minor nature or as warranted by conditions in the<br />

jurisdiction as approved by the building <strong>of</strong>ficial.<br />

2. The provisions <strong>of</strong> Health and Safety <strong>Code</strong> Division 13, Part 6 and the California <strong>Code</strong> <strong>of</strong><br />

Regulations, Title 25, Division 1, Chapter 3, commencing with Section 3000, shall apply to the construction and<br />

inspection <strong>of</strong> factory-built housing as defined in Health and Safety <strong>Code</strong> Section 19971.<br />

S. Section 1707.3 <strong>of</strong> the California Building <strong>Code</strong> is amended to read as follows:<br />

1707.3 Structural Wood. Continuous special inspection is required during field gluing operations <strong>of</strong><br />

elements <strong>of</strong> the seismic-force-resisting system. Periodic special inspection is required for nailing, bolting, anchoring<br />

and other fastening <strong>of</strong> components within the seismic-force-resisting system, including wood shear walls, wood<br />

diaphragms, drag struts, braces, shear panels and hold-downs.<br />

Exceptions:<br />

1. Special Inspection is not required for wood shear walls, shear panels and diaphragms, including<br />

nailing, bolting, anchoring and other fastening to other components <strong>of</strong> the seismic-force-resisting system, where the<br />

fastener spacing <strong>of</strong> the sheathing is more than 4 inches (102 mm) on center (o.c.).<br />

2. Special Inspection is not required if the building is designed in accordance with Tables 2306.2.1(1),<br />

2306.2.1(2) and 2306.3 assuming that the allowable shear values reflected in Tables 2306.2.1(1), 2306.2.1(2) and<br />

2306.3 are reduced by 25%.<br />

T. Section 3109 <strong>of</strong> the California Building <strong>Code</strong> is amended by deleting Sections 3109.1 through 3109.4.3 in<br />

their entirety, amending Sections 3109.4.4.2 and 3109.4.4.3 to read as follows, and adding Section 3109.4.4.9 to read<br />

as follows:<br />

Sections 3109.1 through 3109.4.3 are deleted in their entirety.<br />

Section 3109.4.4.2 Construction Permit; Safety Features Required. Commencing January 1, 2007, except<br />

as provided in Section 3109.4.4.5, whenever a building permit is issued for construction <strong>of</strong> a new pool or spa, or any<br />

building permit is issued for the remodeling <strong>of</strong> an existing pool or spa, at a private single family, duplex or townhouse<br />

building, in addition to an enclosure that meets the requirements <strong>of</strong> Section 3109.4.4.3, it shall also be equipped with<br />

at least one <strong>of</strong> the following six drowning prevention safety features:<br />

1. The pool shall incorporate removable mesh pool fencing that meets American Society for Testing<br />

and Materials (ASTM) specifications F2286 standards in conjunction with a gate that is self-closing and self-latching<br />

and can accommodate a key lockable device.<br />

2. The pool shall be equipped with an approved safety cover that meets all the requirements <strong>of</strong> ASTM<br />

Specification F 1346.<br />

3. The residence shall be equipped with exit alarms on those doors providing direct access to the pool<br />

or spa.<br />

4. All doors providing access to the pool shall be equipped with a self-closing, self-latching device<br />

with a release mechanism placed no higher than 54 inches above the floor.<br />

5. Swimming pool alarms that, when placed in pools, will sound upon detection <strong>of</strong> accidental or<br />

unauthorized entrance into the water. These pool alarms shall meet and be independently certified to the ASTM<br />

Standard F 2208 “Standards Specifications for Pool Alarms” which includes surface motion, pressure, sonar, laser<br />

and infrared type alarms. For purposes <strong>of</strong> this article, “swimming pool alarms” shall not include swimming protection<br />

alarm devices designed for individual use, such as an alarm attached to a child that sounds when the child exceeds a<br />

certain distance or becomes submerged in water.<br />

384-5 rev. 1/1/11