Formula for Vsh<br />

BOOK 1 - WELLCAD BASICS - 127<br />

Formula Parser Dialog Box with Vsh formula created<br />

Click OK to create a new Formula Log named Vsh containing the computed values.<br />

Next we compose the formula for the porosity. We assume that RHOf = 1,<br />

RHOma=2.71 and RHOsh = 2.65. The following formula must be entered:<br />

( (2.71 – {RHOB}) / (2.71 – 1) ) – {Vsh} * ( (2.71 – 2.65) / (2.71 – 1) )<br />

Note that the formula includes the formerly computed Formula Log Vsh. Name the<br />

log PHI and click on OK to create a new Formula Log.<br />

Source logs track 1 and 2 and the computed curves in track 4 and 5