258 - APPENDIX A<br />

www.alt.lu<br />

A depth log with the Reverse flag set can still be selected as reference axis.<br />

Decimal places:<br />

Enter the number of decimals to be displayed in the depth string. Valid numbers are<br />

0 to 5.<br />

Horizontal Grid:<br />

To alter the appearance of the horizontal grid lines you have to define a Spacing<br />

first. The Spacing is measured in units set for the depth axis and is simply a<br />

reference interval for which the frequency of major and minor grid lines as well as<br />

the number of major/minor depth indicators (depth strings) can be set.<br />

Spacing set to 2<br />

Major grid line<br />

Minor grid line<br />

E.g. if a depth scale of 1:200 meters has been chosen with a Spacing set to 2. The<br />

displayed spacing interval will be every 2 meters. If the depth units are changed to<br />

feet, then the Spacing value of 2 will correspond to an interval of 2 feet.<br />

The user can toggle the display of major and/or minor grid lines using the Major &<br />

minor, Major, None options.<br />

More detailed settings for major, minor grid lines and the frequency of depth marker<br />

can be accessed when clicking the <strong>Advanced</strong> button.<br />

Scale:<br />

A scale of 1:100 means that the data acquired over an interval of 100 units (e.g. 100<br />

m depth) will be displayed on 1 unit (e.g. 1 m) of paper (or screen).<br />

Enter a new scale value into the corresponding edit box of the Depth Log Settings<br />

dialog. If the Link scale to master depth option is enabled the actual scale settings<br />

of the master depth axis (see: 1.4.1 Depth Axis) are applied.<br />

If you check the Link scale to master option the depth scale is determined from<br />

the Master Depth axis when making the Depth Log the reference axis of the<br />

borehole document (right click on log title and choose Use As Depth Scale).