BOOK 1 - WELLCAD BASICS - 81<br />

Use Alias Table options:<br />

Alias Tables can be applied when importing data, when loading templates or at any<br />

time when using the Edit > Rename Logs option. For the first two cases the use is<br />

optional and can be enabled by checking the corresponding boxes in the Use Alias<br />

Table field.<br />

For the application of templates several additional options can be set:<br />

Keep existing log name – The alias table will be applied in the background to match<br />

current log title and expected name from the template. But current log titles will not<br />

be overwritten.<br />

Use log name from template – If the current log title appears in the alias list or<br />

corresponds to the expected name it will be set to the name used by the template.<br />

Use log name from alias table – If the current log title appears in the alias list it will be<br />

set to the expected name after the template has been applied.<br />

Format of the Alias Table:<br />

Alias Table *.ini files can be edited using a simple text editor such as Wordpad. The<br />

file consists of three sections [AliasOption], [Alias] and [DefaultUnit].<br />

[AliasOption] contains the general options for the application of alias tables that can<br />

be set in the Use Alias Table section of the dialog box. They should not be edited by<br />

hand.<br />

[Alias] contains the expected name to alias correspondence. The format is:<br />

ExpectedName = Alias 1, Alias 2, Alias 3, …, Alias N<br />

[DefaultUnit] contains alias names and a corresponding unit string. As some alias<br />

names may be a composition of mnemonic and unit string (e.g GR[api])the user can<br />

define the <strong>WellCAD</strong> unit string associated with an alias in this section. E.g. setting<br />

GR[api]= api would force the unit string of the log to be set to api after GR[api] was<br />

renamed to the expected name.<br />

A sample of an Alias Table *.ini file is shown below:<br />

[AliasOption]<br />

ImportRenameLog=yes<br />

TemplateUseAlias=no<br />

TemplateRenameLog=no<br />

ImportFileUsingAliasTable=yes<br />

ApplyTemplateUsingAliasTable=yes<br />

RenameLogApplyingTemplate=ChangeFromTemplate