APPENDIX A - 371<br />

The Analysis Log can present its data in three different styles – Dynamic Bar,<br />

Fixed Bar and Line. For all display styles you can choose whether you want to<br />

show lines separating the components from each other or not. Check the Display<br />

Border Lines option if you want to see them.<br />

Dynamic Bar:<br />

Dynamic Bar style<br />

The upper and lower limits of adjacent data points are linked together to form a<br />

continuous dynamic bar. Please have a look to the <strong>Advanced</strong> settings to know if the<br />

data points depth belongs to the top, middle or bottom of the bar.<br />

Depending on your sample rate and document depth scale the bars appear as very<br />

small lines only.<br />

Fixed Bar:<br />

Fixed Bar style<br />

Each data point is displayed as a fixed discrete bar. The thickness of the bar can be<br />

defined and may be changed from 0.1 to 5.0 mm thickness by entering the<br />

corresponding value (measured in mm/10) into the edit box. Please have a look to