356 - APPENDIX A<br />

www.alt.lu<br />

Display Styles:<br />

Image Log displayed in Color Image (left), Shifted Curve (middle) and Stacked Curve (right) style.<br />

Inserting a new Image Log:<br />

Image Logs are automatically created when files are imported. During the import of<br />

DLIS files the type of Image Log (integer, float 2 or float 4) can be specified. Other<br />

import algorithms create the integer type Image Log by default. To check which type<br />

of Image Log you are working on, simply open the Main Settings dialog box. The<br />

dialog box title states the type of log.<br />

It is also possible to create a new Image Log using the Insert New Log command<br />

from the Edit menu. The Logs Selection dialog opens listing all Well Logs<br />

contained in your Borehole Document. The new Image Log, which is always of type<br />

float 4, will be created from your selection of Well Logs. E.g. you want to display a 4<br />

arm caliper measurement for which you have 4 Well Logs in your document. In the<br />

Logs Selection dialog box select the corresponding Well Logs. As you have 4 Logs<br />

you will get 4 data traces in the Image Log (at 0°, 90°, 180° and 270°). The logs are<br />

taken in the order as they are listed in the Logs Selection dialog box which<br />

corresponds to the order the logs were added to the Borehole Document. To<br />

change the order in the Borehole Document use the Move Up / Down option<br />

from the Layout Bar (see 1.3.2.5 Layout Toolbar).