of the lift is due almost entirely to these stages<br />
and is not in any way important since these are<br />
recyclable materials. In the operational phase,<br />
the use of electricity is decisive and the energy<br />
efficiency of the plant is relevant.<br />
For this reason, PCRs for lifts require the class<br />
to be declared, calculated according to<br />
ISO 25745-2, which Otis conservatively<br />
declares to be B, while all other EPDs declare<br />
A. In reality, even the energy efficiency<br />
classification depends on the category of use of<br />
the system, so it cannot be declared in advance<br />
with certainty.<br />
nella vita dell’ascensore è dovuta quasi tutta a<br />
queste fasi, e non è in assoluto importante, perché<br />
appunto si tratta di materiali riciclabili. Nella<br />
fase operativa, è determinante l’uso dell’energia<br />
elettrica ed è rilevante l’efficienza energetica<br />
dell’impianto. Per questa ragione le PCR per<br />
ascensori prevedono che ne venga dichiarata la<br />
classe, calcolata secondo la ISO 25745-2, che la<br />
Otis dichiara prudenzialmente essere la B, mentre<br />
tutte le altre EPD dichiarano la A. In realtà anche<br />
la classificazione di efficienza energetica dipende<br />
dalla categoria d’uso dell’impianto, perciò non può<br />
essere dichiarata a priori per certa, ma tant’è.<br />
On these points the other companies report similar<br />
information for their products qualitatively. The<br />
impact of transport in the various phases as a<br />
whole is not particularly significant, however<br />
Fujitec, which manufactures the system in the<br />
East and imports it to the Netherlands by ship,<br />
provides more details on this. The transport<br />
phase A4* is only relevant for the environmental<br />
impact indicators ODP (presence of ozone in the<br />
stratosphere), AP (soil and water acidification<br />
potential), EP (eutrophication potential) and<br />
POCP (photochemical ozone creation potential),<br />
mainly due to the impurities contained in the fuel<br />
used by the ships.<br />
Schindler, for its 1000, 1000 Plus, 3000 and<br />
2000 Plus, focuses on two environmental<br />
impact indicators, namely GWP tot<br />
(total climate<br />
change) and ADPF (use of fossil resources),<br />
the relevant values of which derive from phase<br />
A1* (raw materials), phase B6* (especially<br />
the consumption of fossil resources, used to<br />
produce the electricity that powers the plant)<br />
and, to a lesser extent, phase B2* maintenance.<br />
TKE for its Sinergy 100 is one of the few<br />
companies that emphasises how crucial the<br />
energy mix is. It is also the only one among<br />
the EPDs examined which, as a potential<br />
for improvement, suggests a reduction in lift<br />
weight and it is no coincidence that this is<br />
the case for the lift with the lowest assumed<br />
Su questi punti le altre aziende, per i loro<br />
prodotti, qualitativamente dicono le stesse<br />
cose. L’impatto dei trasporti nelle varie fasi nel<br />
complesso non è molto significativo, ma Fujitec,<br />
che produce l’impianto in Oriente per importarlo<br />
in Olanda via nave, dettaglia meglio questo<br />
aspetto: la fase di trasporto A4* è rilevante<br />
solo per gli indicatori di impatto ambientale<br />
ODP (presenza di ozono nella stratosfera),<br />
AP (potenziale di acidificazione del suolo e<br />
dell'acqua), EP (Potenziale di eutrofizzazione)<br />
e POCP (potenziale di creazione di ozono<br />
fotochimico), soprattutto a causa delle impurità<br />
contenute nel combustibile usato dalle navi.<br />
Schindler, per i suoi 1000, 1000 Plus, 3000 e<br />
2000 Plus, focalizza l’attenzione su due indicatori<br />
di impatto ambientale, che sono il GWP tot<br />
(cambiamento climatico totale) e l’ADPF (l’uso delle<br />
risorse fossili), i cui valori rilevanti derivano dalla<br />
fase A1* (materie prime), dalla fase B6* (specie<br />
quanto a consumo delle risorse fossili, utilizzate per<br />
produrre l’elettricità che alimenta l’impianto) e, in<br />
misura minore, dalla fase B2* di manutenzione.<br />
TKE per il suo Sinergy 100 è una delle poche<br />
aziende che sottolinea come sia cruciale il mix<br />
energetico di riferimento. Essa è anche l’unica<br />
tra le EPD esaminate che, come potenzialità di<br />
miglioramento, suggerisce una diminuzione del<br />
peso dell’impianto e non è un caso che ciò venga<br />
fatto per quell’ascensore di cui si ipotizza il<br />
<strong>2023</strong> MAY | JUNE • MAGGIO | GIUGNO <strong>2023</strong><br />
ELEVATORIMAGAZINE.COM<br />
25