4.3.3 Configuration with IE/PB Link<br />

<strong>Configuring</strong> PROFINET IO Devices<br />

You can use the IE/PB link to connect PROFIBUS DP configurations to<br />

PROFINET IO.<br />

From the st<strong>and</strong>point of the CPU, PROFIBUS DP slaves are on the same network<br />

as the IE/PB link. These slaves have the same device names <strong>and</strong> IP addresses as<br />

the IE/PB link, but do have different device numbers. In addition, they also still<br />

have specific PROFIBUS addresses.<br />

In addition to the device number, the symbol for the IE/PB link also shows the<br />

PROFIBUS address, since this device has two address schemas.<br />

(1) Device number of the IE/PB link<br />

(2) Device number <strong>and</strong> PROFIBUS address of the DP slave<br />

H<strong>and</strong>ling device numbers <strong>and</strong> PROFIBUS addresses at the master system<br />

When IO devices are positioned, <strong>STEP</strong> 7 assigns the same number for the device<br />

number <strong>and</strong> the PROFIBUS address.<br />

To get an overview of the device numbers <strong>and</strong> the PROFIBUS addresses being<br />

used, double-click the symbol for the IE/PB link <strong>and</strong> select the "Device Numbers"<br />

tab.<br />

Each line in the "Device Numbers" tab represents a DP slave. If you select a line<br />

<strong>and</strong> then click the "Change" button or double-click a line, a dialog box is displayed<br />

in which you can change the device number.<br />

You can change the PROFIBUS address in the usual manner:<br />

1. Double-click the symbol for the DP slave to display its properties dialog.<br />

2. In the "General" tab, click the "PROFIBUS" button.<br />

3. In the next dialog box, change the PROFIBUS address.<br />

Restrictions<br />

The configuration described above applies to DP slaves on the PROFIBUS subnet<br />

of an IE/PB link, subject to the following restrictions:<br />

• No IE/PB link can be inserted<br />

• No DP/PA link can be inserted<br />

• No Y-link can be inserted<br />

• No CiR compatibility<br />

• No redundant slaves can be inserted<br />

• No isochrone mode/constant bus cycle time cane be configured<br />

<strong>Configuring</strong> <strong>Hardware</strong> <strong>and</strong> <strong>Communication</strong> <strong>Connections</strong> with <strong>STEP</strong> 7<br />