<strong>Configuring</strong> IRT <strong>Communication</strong><br />

<strong>Configuring</strong> the Receiver<br />

1. Open the property sheet for the IO controller (double-click the corresponding<br />

row in the configuration table in HW Config).<br />

2. Select the "Receiver" tab.<br />

3. Click the "New" button.<br />

4. In the property sheet for the receiver, click the "Assign Sender" button.<br />

5. In the "Assign Sender" dialog box that is displayed, select the data range of the<br />

desired station. This is the data range to be received by the local CPU.<br />

6. Confirm your settings with "OK".<br />

7. In the property sheet for the receiver, enter the start address of the address<br />

area that will be used when receiving.<br />

The length of the address area should not be changed since it will be<br />

automatically adjusted to the length of the sender range.<br />

Note: The configuration can only be compiled if the sender range <strong>and</strong> the<br />

receiver range have the same lengths!<br />

8. Repeat steps 3 to 7 for additional receiver ranges .<br />

9. Each assigned sender has a diagnostic address reserved for it. The receiver<br />

can detect failure of the sender by means of its diagnostic address.<br />

Click the "Diagnostic Addresses" button to edit these addresses<br />

5.8 Downloading an IRT Configuration<br />

The configuration data must be downloaded to all devices that are involved in IRT<br />

communication.<br />

Before downloading, first perform a consistency check <strong>and</strong> eliminate any errors<br />

that may exist.<br />

Recommendation<br />

Sync domains are not limited to one station. Download the IRT configuration from<br />

the network configuration (NetPro).<br />

To do this, select the Ethernet subnet <strong>and</strong> then select the PLC > Download to<br />

Current Project> Stations on the Subnet menu comm<strong>and</strong>.<br />