Networking Stations<br />

11.5 Importing <strong>and</strong> Exporting Stations in the Network View<br />

Introduction<br />

As of <strong>STEP</strong> 7 V5.1, Service Pack 1, in the network view, you can export <strong>and</strong> import<br />

as a text file (ASCII file) those station configurations that have network data but do<br />

not have connection data.<br />

If you export several stations of a <strong>STEP</strong> 7 project that are networked with each<br />

other <strong>and</strong> then import them into another project, these stations are again<br />

networked with each other as they were in the original project.<br />

Applications<br />

• Can be distributed by means of electronic media (for example, e-mail)<br />

• Can be read into future <strong>STEP</strong> 7 versions<br />

• Export file can be printed out with word processing systems or processed<br />

further for documentation purposes<br />

Which Network Objects Can Be Exported Or Imported?<br />

You can export <strong>and</strong> import SIMATIC 300, SIMATIC 400, SIMATIC 400H, <strong>and</strong><br />

SIMATIC PC stations.<br />

What Is Exported/Imported?<br />

With import <strong>and</strong> export from the network view, data can be exported/imported that<br />

are required for configuration <strong>and</strong> parameter assignment of the modules, as well as<br />

the network configuration.<br />

The network configuration includes:<br />

• Interface parameter assignments (for example, subnet screen <strong>and</strong> router<br />

settings of an Industrial Ethernet interface, bus parameters of a PROFIBUS<br />

interface)<br />

• Assignment to the subnets<br />

• <strong>Connections</strong><br />

Not included:<br />

• Data that are managed by means of other applications (for example, programs,<br />

global data)<br />

• <strong>Connections</strong><br />

• CPU password assigned as parameter<br />

• Data that apply to more than one station (for example, the linking of intelligent<br />

DP slaves or configuration for direct data exchange)<br />

Note<br />

If your configuration contains modules from older option packages, it is possible<br />

that not all data of the module are included in the export function. In this case,<br />

check to see if the module data are complete after the import is finished.<br />

<strong>Configuring</strong> <strong>Hardware</strong> <strong>and</strong> <strong>Communication</strong> <strong>Connections</strong> with <strong>STEP</strong> 7<br />