<strong>Configuring</strong> <strong>Connections</strong><br />

12.12 <strong>Configuring</strong> <strong>Connections</strong> to Partners in the Same<br />

Project<br />

12.12.1 Connection Types for Connection Partners in the Same Project<br />

Selecting the Connection Type for Connection Partners in the Same Project<br />

The connection type is dependent on the subnet <strong>and</strong> the transfer protocol via<br />

which the connection is established, <strong>and</strong> on the automation family to which the<br />

connection partners belong.<br />

The blocks (SFBs, FBs, or FCs) you can use depend on the connection type.<br />

The following table should make it easier for you to select the connection type for<br />

the connection you want to establish.<br />

Connection Type Subnet Type Connection between<br />

SIMATIC...<br />

S7 connection MPI,<br />

PROFIBUS,<br />

Industrial Ethernet<br />

S7 connection, faulttolerant<br />

PTP<br />

Connection<br />

PROFIBUS,<br />

Industrial Ethernet<br />

Point-to-point<br />

(computer protocol<br />

RK 512/3964(R))<br />

FMS connection PROFIBUS<br />

(FMS protocol)<br />

FDL connection<br />

ISO<br />

transport link<br />

PROFIBUS<br />

(FDL protocol)<br />

Industrial Ethernet<br />

(ISO Transport<br />

protocol)<br />

S7 - S7, S7 - PG/PC,<br />

S7 - PG/PC with WinCC<br />

with MPI also: M7 - M7,<br />

M7 - S7, M7 - PG/PC<br />

S7 - partner in another project<br />

(S7, PG/PC with WinCC)<br />

S7(H) - S7(H),<br />

S7(H) - PC station (H)<br />

S7 - S7, S7 - S5,<br />

S7 - non-Siemens device<br />

S7 - partner in another project<br />

(S7, no Siemens device)<br />

S7 - S7, S7 - S5, S7 - PG/PC, S7<br />

- no Siemens device, S7 -<br />

broadcast to all nodes<br />

S7 - partner in another project<br />

(S7, S5, PG/PC, no Siemens<br />

device)<br />

S7 - S7, S7 - S5, S7 - PC/PG, S7<br />

-non-Siemens device<br />

S7 - partner in another project<br />

(S7, S5, PG/PC, non-Siemens<br />

device)<br />

S7 - S7, S7 - S5, S7 - PC/PG, S7<br />

- non-Siemens device, S7 -<br />

unspecified<br />

S7 - partner in another project<br />

(S7, S5, PG/PC, non-Siemens<br />

device, unspecified)<br />

SFB/FB/FC<br />

SFBs USEND,<br />

URCV, BSEND,<br />

BRCV, GET,<br />

PUT, START,<br />

STOP, RESUME,<br />

STATUS,<br />

USTATUS<br />

SFBs USEND,<br />

URCV, BSEND,<br />

BRCV, START,<br />

STOP, RESUME,<br />

STATUS,<br />

USTATUS<br />

SFBs BSEND,<br />

BRCV, GET,<br />

PUT, STATUS,<br />

PRINT<br />

FBs READ,<br />

WRITE,<br />

IDENTIFY,<br />

OSTATUS,<br />

REPORT<br />

FCs AG_SEND,<br />

AG_RECV,<br />

AG_LSEND,<br />

AG_LRECV<br />

FCs AG-SEND,<br />

AG-RECEIVE<br />

AG_LSEND,<br />

AG_LRECV,<br />

AG_LOCK,<br />

AG_UNLOCK;<br />

<strong>Configuring</strong> <strong>Hardware</strong> <strong>and</strong> <strong>Communication</strong> <strong>Connections</strong> with <strong>STEP</strong> 7<br />