Possible problems when working with distributed projects<br />

Working With Projects in the Multiproject<br />

The PG/PC assignment is not visible if the allocation of projects is changed <strong>and</strong> a<br />

project is opened on a PG/PC on which it was not created.<br />

Nonetheless, the configured PG/PC object still maintains the "assigned" status -<br />

but with the "wrong" PG/PC.<br />

In this case you must clear the existing assignment <strong>and</strong> then reassign the PG/PC<br />

object. Online access to modules available within the multiproject is then possible<br />

without any problem.<br />

Tip for working with distributed projects<br />

If more than one of the team members want to access the PLCs online on their<br />

PG, it would be useful to create one "PG/PC" or "SIMATIC PC station" object in the<br />

multiproject <strong>and</strong> then set up an assignment for each one of the PGs.<br />

Depending on which PG has opened the project, SIMATIC Manager indicates only<br />

the object assigned to this PG with a yellow arrow.<br />

<strong>Configuring</strong> <strong>Hardware</strong> <strong>and</strong> <strong>Communication</strong> <strong>Connections</strong> with <strong>STEP</strong> 7<br />

A5E00706939-01 16-13