Basics of <strong>Configuring</strong> <strong>Hardware</strong> with <strong>STEP</strong> 7<br />

The following table provides information on each individual slave family:<br />

DP Slave Type Exchangeable Conditions for Exchange<br />

DP slaves whose properties<br />

are specified by GSD files<br />

(additional information...)<br />

No -<br />

DP-As-i Link No -<br />

DP/PA Link Yes Maximum configuration of the DP master cannot be<br />

exceeded (I/O address space, number of slots)<br />

A redundantly operated DP/PA link can only be<br />

exchanged for a DP/PA link that can be operated<br />

redundantly.<br />

ET 200L SC <strong>and</strong> IM SC Yes You must be able to put all inserted modules into the<br />

new DP slave.<br />

ET 200M (IM 153-x) Yes Cannot be exchanged if:<br />

• For the old ET 200M, the function "Change<br />

Modules during Operation" was activated <strong>and</strong> the<br />

new ET 200M does not support the function<br />

• CPs/FMs with their own MPI address (for example,<br />

FM 353)<br />

• Modules are inserted in the old ET 200M which<br />

cannot be inserted in the new ET 200M<br />

• The old ET 200M was operated redundantly <strong>and</strong><br />

the new ET 200M cannot be operated redundantly<br />

ET 200S (IM 151-1) Yes Cannot be exchanged with IM 151/CPU<br />

ET 200S (IM 151/CPU) Yes Cannot be exchanged with IM 151-1<br />

ET 200X<br />

Yes You must be able to put all inserted modules into the<br />

(X-BM 141.., X-BM 142..)<br />

new DP slave.<br />

An X-BM 143/DESINA cannot be exchanged for other<br />

ET 200X basic modules <strong>and</strong> vice versa<br />

Cannot be exchanged with X-BM 147/CPU<br />

ET 200X BM 147/CPU Yes Cannot be exchanged with X-BM 141..., X-BM 142...<br />

<strong>and</strong> X-BM 143...<br />

Which DP Slaves Are Specified by GSD files?<br />

DP slaves whose properties are specified by GSD files (device database files) are<br />

located in the <strong>Hardware</strong> Catalog in the "Other Field Devices" folder or also in the<br />

"CP 342-5 as DP-Master" folder, for example. Those DP Slaves (also called<br />

"St<strong>and</strong>ard Slaves") can be identified by specifying the GSD file or type file in the<br />

"Order no." row or in the "DP Slave properties" dialog, "General" tab.<br />

<strong>Configuring</strong> <strong>Hardware</strong> <strong>and</strong> <strong>Communication</strong> <strong>Connections</strong> with <strong>STEP</strong> 7<br />

1-16 A5E00706939-01