Connection Type Subnet Type Connection between<br />

SIMATIC...<br />

ISO-on-TCP<br />

connection<br />

Industrial Ethernet<br />

(TCP/IP protocol)<br />

TCP connection Industrial Ethernet<br />

(TCP/IP protocol)<br />

UDP connection<br />

Industrial Ethernet<br />

(TCP/IP protocol)<br />

S7 - S7, S7 - S5,<br />

S7 - PC/PG,<br />

S7 - non-Siemens device,<br />

S7 - unspecified<br />

S7 - partner in another project<br />

(S7, S5, PG/PC, non-Siemens<br />

device, unspecified)<br />

S7 - S7, S7 - S5,<br />

S7 - PC/PG,<br />

S7 - non-Siemens device,<br />

S7 - unspecified<br />

S7 - partner in another project<br />

(S7, S5, PG/PC, non-Siemens<br />

device, unspecified)<br />

S7 - S7, S7 - S5, S7 - PG/PC, S7<br />

- non-Siemens device, S7 -<br />

unspecified<br />

S7 - partner in another project<br />

(S7, S5, PG/PC, non-Siemens<br />

device, unspecified)<br />

S7 - unspecified (S7 - mail<br />

<strong>Configuring</strong> <strong>Connections</strong><br />

SFB/FB/FC<br />

FCs AG-SEND,<br />

AG-RECEIVE<br />

AG_LSEND,<br />

AG_LRECV,<br />

AG_LOCK,<br />

AG_UNLOCK<br />

FCs AG_SEND*,<br />

AG_RECV*,<br />

AG_LSEND**,<br />

AG_LRECV**<br />

AG_LOCK<br />

AG_UNLOCK<br />

FCs AG-SEND,<br />

AG-RECEIVE<br />

AG_LSEND,<br />

AG_LRECV<br />

E-mail connection Industrial Ethernet<br />

FCs AG-SEND,<br />

(TCP/IP protocol) server)<br />

AG_LSEND<br />

* The FCs AG_SEND <strong>and</strong> AG_RECV here can only be used for S7-300 (this<br />

depends on release number of the CP, see the documentation for the CP).<br />

** The FCs AG_LSEND <strong>and</strong> AG_LRECV here can generally be used for<br />

S7-400, <strong>and</strong> in addition for S7-300 (this depends on release number of the<br />

CP, see the documentation for the CP).<br />

Special Feature: Connection to Broadcast <strong>and</strong> Multicast Nodes<br />

For special connection types there is the option of selecting not just one connection<br />

partner, but several ones (broadcast <strong>and</strong> multicast nodes). These options are<br />

described in the SIMATIC NET (NCM S7) manuals. The connection partners "all<br />

broadcast nodes" or "all multicast nodes" are listed in the dialog box for entering a<br />

new connection.<br />

• You can set up a connection to "all broadcast nodes" (simultaneous sending to<br />

all broadcast receivers) for the connection types FDL connection <strong>and</strong> UDP<br />

connection.<br />

• You can set up a connection to "all multicast nodes" (simultaneous sending to<br />

several nodes) for the connection types FDL connection <strong>and</strong> UDP connection.<br />

<strong>Configuring</strong> <strong>Hardware</strong> <strong>and</strong> <strong>Communication</strong> <strong>Connections</strong> with <strong>STEP</strong> 7<br />

A5E00706939-01 12-27