<strong>Configuring</strong> <strong>Connections</strong><br />

12.12.3.4 Deleting One or More <strong>Connections</strong><br />

Requirement:<br />

Procedure<br />

You must be in the network view of NetPro.<br />

1. Select the connections you wish to delete.<br />

2. Select the menu comm<strong>and</strong> Edit > Delete.<br />

If local ID <strong>and</strong> partner ID for the connection were entered in the connection<br />

table, <strong>STEP</strong> 7 also deletes the connection in the table for the connection<br />

partner.<br />

3. Download the connection tables with the deleted connections to the relevant<br />

programmable module. (To delete all the connections of a programmable<br />

module, you must download an empty connection table to the module.)<br />

12.12.3.5 Copying <strong>Connections</strong><br />

Introduction<br />

<strong>Connections</strong> are not copied individually but always in context with the project or the<br />

station.<br />

You can copy the following:<br />

• Entire projects<br />

• One or more stations within a project or beyond the boundaries of a project<br />

Requirement<br />

The SIMATIC Manager must be open.<br />

Copying a Project<br />

When you copy a project, all configured connections are also copied. There are no<br />

settings required for the copied connections because the connections remain<br />

consistent.<br />

Copying a Station<br />

When you copy one or more stations within the project boundaries or beyond them,<br />

you may have to reassign the connection partners to the local node (modifying a<br />

connection).<br />

If no connection partner exists for a connection, you will see this in the connection<br />

table, since the row of the connection partner will be displayed in bold.<br />

<strong>Connections</strong> between stations that are copied beyond the project boundaries<br />

remain in tact <strong>and</strong> consistent if the relevant subnets between these stations are<br />

copied along with them.<br />