<strong>Configuring</strong> the Distributed I/O (DP)<br />

3.2 Where Are the DP Slaves in the <strong>Hardware</strong> Catalog<br />

Window?<br />

All DP slaves can be found in the "<strong>Hardware</strong> Catalog" window under the<br />

"PROFIBUS-DP" folder.<br />

The following applies here:<br />

The DP master is...<br />

• ...a SIMATIC 300 or SIMATIC 400 CPU with integrated PROFIBUS-DP<br />

interface, a PROFIBUS CP (without CP 342-5DA00) in a SIMATIC 300/400 or a<br />

SIMATIC PC station with a PROFIBUS CP (without CP 5611/CP 5613)<br />

The DP slaves appear under their "family name" (e.g. PROFIBUS-<br />

DP\ET 200B).<br />

• ...a CP 342-5DA00 with PROFIBUS-DP interface or an SIMATIC PC station<br />

with CP 5611/CP 5613:<br />

The DP slaves appear either in the "DP V0 Slaves" folder <strong>and</strong> then under their<br />

family name<br />

(e.g. PROFIBUS DP\DP V0 Slaves\ET 200B).<br />

The "DP V0 Slaves" contains the DP slaves represented by their GSD file or type<br />

file (referred to as "St<strong>and</strong>ard Slaves").<br />

Folders designated with the family name <strong>and</strong> located directly under PROFIBUS DP<br />

(e.g. PROFIBUS DP\ET 200B) usually contain the DP slaves whose properties are<br />

represented by internal <strong>STEP</strong> 7 information (referred to as "S7 Slaves").<br />

The DP slave was purchased separately (with a new *.GSD file)<br />

The DP slave will appear under "Other Field Devices" after you have installed the<br />

*.GSD file.<br />

The DP slave is an intelligent DP slave<br />

Examples: You can configure stations as a DP slave with:<br />

• CP 342-5 DP<br />

• CPU 315-2 DP, CPU 316-2 DP, CPU 318-2 DP<br />

• Basic submodule ET 200X (BM 147/CPU)<br />

• IM 151/CPU (ET 200S)<br />

The DP slave appears under the "Configured Stations" folder after configuring the<br />

station. The procedure (how does a station appear in the "Configured Stations"<br />

folder?) is described in detail in the section about configuring the intelligent DP<br />

slaves.<br />

<strong>Configuring</strong> <strong>Hardware</strong> <strong>and</strong> <strong>Communication</strong> <strong>Connections</strong> with <strong>STEP</strong> 7<br />

3-4 A5E00706939-01

Hooray! Your file is uploaded and ready to be published.

Saved successfully!