<strong>Configuring</strong> a SIMATIC PC Station (SIMATIC PC based)<br />

Procedure<br />

The following figure shows the structure of the <strong>Hardware</strong> Catalog for SIMATIC PC<br />

stations:<br />

1. In the SIMATIC Manager, insert a SIMATIC PC station in your project) menu<br />

comm<strong>and</strong> Insert > SIMATIC PC Station).<br />

2. Change the name of the SIMATIC PC station as you see fit.<br />

If the computer that you are now using for configuration <strong>and</strong> for loading stations<br />

is identical with the SIMATIC PC station inserted in the SIMATIC Manager,<br />

then the name of this station must be identical with the name specified in the<br />

Component Configuration Editor. Only then is the SIMATIC PC station properly<br />

"assigned" in the project; in other words, it is then recognized in the SIMATIC<br />

Manager <strong>and</strong> in the network view as an assigned SIMATIC PC station.<br />

3. Double-click the SIMATIC PC station object <strong>and</strong> then the Configuration object.<br />

HW Config opens for editing the station configuration. Row 125 of the<br />

configuration table is occupied by the station manager (cannot be deleted).<br />

4. Use a drag-<strong>and</strong>-drop operation to insert those components into the<br />

configuration table of the SIMATIC PC station that represent the configuration<br />

of the real PC. The components are located in the "<strong>Hardware</strong> Catalog" window<br />

under SIMATIC PC Station:<br />

- Software PLC WinLC in slot 2 (for information on exp<strong>and</strong>ed configuration<br />

options, see Slot Rules for PC-based SIMATIC Controllers)<br />

- Slot PLC CPU 41x-2 PCI (WinAC Slot 412 <strong>and</strong> WinAC Slot 416) in slot 3<br />

(for information on exp<strong>and</strong>ed configuration options, see Slot Rules for PCbased<br />

SIMATIC Controllers)<br />

- CPs in one of the slots from 1 to 32 (if necessary, observe the restrictions<br />

in the Product Information for the current slot-CP!)<br />

- SW placeholder for configuring connections such as "User Application" or<br />

HMI components (if installed) also in slots 1 to 32<br />

- OPC Server for OPC Clients accessing the variables of remote automation<br />

systems via configured connections also in slots 1 to 32.<br />

<strong>Configuring</strong> <strong>Hardware</strong> <strong>and</strong> <strong>Communication</strong> <strong>Connections</strong> with <strong>STEP</strong> 7<br />